GW Instek SFG-830 User Manual User Manual
Page 22
SFG-830 p.19
(1) Common Commands of IEEE488.2
Command
Function
Parameter
*CLS
Clear status command
Nil
*ESE
Standard event status enable command
Numerical data
*ESE?
Standard event status enable query
Nil
*ESR?
Standard event status register query
Nil
*IDN?
Identification query
Nil
*OPC
Operation complete command
Numerical data
*OPC?
Operation complete query
Nil
*RCL
Recall command
Integer among 0 ~ 9
*RST
Reset command
Nil
*SAV
Save command
Integer among 0 ~ 9
*SRE
Service request enable command
Numerical data
*SRE?
Service request enable query
Nil
*STB?
Read status byte query
Nil
*TST?
Self-test query
Nil
*WAI
Wait-to-continue command
Nil
Note :
c The range of numerical data is 0 ~ 255.
d For more details, please refer to appendix 1.
(2) Commands of the Instrument
Command
Function
Parameter
SYSTem:ERR?
Check the type of error messages
Nil
SOURce:FUNCtion:SINusoid
Select sine waves
Nil
SOURce:FUNCtion:SQUare
Select square waves
Nil
SOURce:FUNCtion:TRIangle
Select triangle waves
Nil
SOURce:FUNCtion:RAMP
Select ramp waves
Nil
SOURce:FUNCtion:ARBitrary
Select arbitrary waves
Nil
SOURce:FUNCtion:WAVEform?
Check the present waveform
Nil
SOURce:FREQuency:SYNThesis
Set the frequency of synthetic waves
Numeric data
SOURce:FREQuency:SYNThesis?
Check the frequency of synthetic waves
Nil