41
Figure 5-2: Sampling and wiring application for the output terminal of
European Regulation
1) CV Regulation
When the voltage drop between the (+) output terminal and positive
sensing point increases 1V, its voltage Load regulation must be add
another 5mV.
2) Output Noise
A voltage load regulation effects could be occurred by any noise
which interferes the output terminal of the power supply. Therefore,
it will be helpful to reduce the output noise by paralleling two sensing
circuit of (S+) and (S-) and separating each other adequately, then
connect a single end to the ground terminal of power supply. The
relative configuration is as follows:
PSM-SERIES PROGRAMMABLE POWER SUPPLY
USER MANUAL
⎯ ⎯
42
Figure 5-3
z
Panel Lock Key:
Press [LOCK] key can lock up the panel control knob to prevent any
setting change, now the [OUTPUT] key still works. Press again
[LOCK] key for a few seconds can release the lock setting.
z
GPIB and RS232 interface setting:
Please refer to the PSM-SERIES Programmer manual for detailed
description.
RS232 cable configuration:
Figure 5-4 RS-232 Cable Configuration
Please enter to our web site for updated information: