beautypg.com

GW Instek PSM-Series User Manual User Manual

Page 24

background image

PSM-SERIES PROGRAMMABLE POWER SUPPLY

USER MANUAL

⎯ ⎯

41

Figure 5-2 Sampling and wiring application for the output terminal of

European Regulation

1) CV Regulation

When the voltage drop between the (+) output terminal and positive

sensing point increases 1V, its voltage Load regulation must be add

another 5mV.

2) Output Noise

A voltage load regulation effects could be occurred by any noise

which interferes the output terminal of the power supply. Therefore,

it will be helpful to reduce the output noise by paralleling two sensing

circuit of (S+) and (S-) and separating each other adequately, then

connect a single end to the ground terminal of power supply. The

relative configuration is as follows:

PSM-SERIES PROGRAMMABLE POWER SUPPLY

USER MANUAL

⎯ ⎯

42

Figure 5-3

z

Panel Lock Key:

Press [LOCK] key can lock up the panel control knob to prevent any

setting change, now the [OUTPUT] key still works. Press again

[LOCK] key for a few seconds can release the lock setting.

z

GPIB and RS232 interface setting:

Please refer to the PSM-SERIES Programmer manual for detailed

description.

RS232 cable configuration:

Figure 5-4 RS-232 Cable Configuration

Please enter to our web site for updated information:

http://www.goodwill.com.tw