PSM-SERIES PROGRAMMABLE POWER SUPPLY

USER MANUAL

⎯ ⎯

25

z AUTO RANGE

AUTO RANGE Setting method: Press [SHIFT][AUTO RANGE] , use

knob to select the item for setting change.

For example: Set the AUTO RANGE to: START : 00 ; CEASE : 99 ;

CYCLE : 99999。

Press [SHIFT][AOTU RANGE] to enter AUTO RANGE setting item

selection, first select START and press [ENTER], then input [0][0]

[ENTER] to complete the change. Then input [9][9][ENTER] to CEASE

setting item to complete CEASE setting. Furthermore, input [9][9][9][9][9]

[ENTER] to CYCLE setting item to complete CYCLE setting. After

proceeding above setting, select SAVE to store the setting or select EXIT

to exit the setting without storing.

PSM-SERIES PROGRAMMABLE POWER SUPPLY

USER MANUAL

⎯ ⎯

26