PSM-SERIES PROGRAMMABLE POWER SUPPLY
USER MANUAL
⎯ ⎯
23
z DELAY : The Auto mode setting for the voltage/current Delay time
Setting method: Press [SHIFT] [DELAY] to appear the “MIN.” setting item
selection, then input setting value and press [ENTER] to “SEC.” setting
item selection, input setting value and press [ENTER] to change Delay
setting.
Remark:
1) The minimum unit of the “SEC.” Setting picture is at 0.1 sec.
2) The Delay setting is effective only under the Auto running
operation, therefore, during the storage proceeding, the Delay
setting will be saved to the memory address simultaneously.
For example: Set the Delay time to 9 minutes and 9.9 seconds.
Press [SHIFT] [DELAY] to appear “MIN” setting item, input [9] and
[ENTER], then select “SEC” setting item and input [9][.][9][ENTER] to
complete DELAY setting.
PSM-SERIES PROGRAMMABLE POWER SUPPLY
USER MANUAL
⎯ ⎯
24
z RECALL : Recall the setting data from the memory bank
Remark:
1) After RECALL setting, it needs to press again [SHIFT]
[RECALL] to leave the function.
2) When query the stored setting data, in order to avoid personal
injury and damaging the machine, it is suggested to turn off
the output.
Recall Setting method: Press [SHIFT][RECALL](Recall Data setting
from the memory bank), use knob or number key to input the memory
address.
For example: Recall the setting data from the memory address of 01.
Press [SHIFT][RECALL], get into RECALL setting, then press
[0][1][ENTER] to complete Recall.