System:configure:bleeder[:state, System:configure:btrip[:immediate, System:configure:btrip:protection – GW Instek PSW-Series Programming & Command manual User Manual
Page 80

PSW Series Programming Manual
80
OFF
Turns the buzzer off.
1
ON
Turns the buzzer on.
Return parameter
Returns the buzzer status.
SYSTem:CONFigure:BLEeder[:STATe]
Set
Query
Description
Sets or queries the status of the bleeder resistor.
Syntax
Query Syntax
SYSTem:CONFigure:BLEeder[:STATe] {OFF|ON|0|1}
SYSTem:CONFigure:BLEeder[:STATe]?
Parameter
0
OFF
Turns the bleeder resistor off.
1
ON
Turns the bleeder resistor on.
Return parameter
Returns bleeder resistor status.
SYSTem:CONFigure:BTRip[:IMMediate]
Set
Description
Trips the power switch trip (circuit breaker) to
turn the unit off (shut down the power).
Syntax
SYSTem:CONFigure:BTRip[:IMMediate]
SYSTem:CONFigure:BTRip:PROTection
Set
Query
Description
Enables/Disables the power switch trip (circuit
breaker) when the OVP or OCP protection settings
are tripped. This setting only applies after power
has been reset.
Syntax
SYSTem:CONFigure:BTRip:PROTection {OFF|ON|0|1}
Query Syntax
SYSTem:CONFigure:BTRip:PROTection?
Parameter
0
OVP or OCP.
OFF
Disables the power switch trip for OVP or
OCP.
1
OVP or OCP.