GW Instek PSW-Series Programming & Command manual User Manual
Page 107

REMOTE CONTROL
107
-112 Program 
mnemonic too 
long 
The header contains more that twelve 
characters (see IEEE 488.2, 7.6.1.4.1). 
-113 Undefined 
header 
The header is syntactically correct, but it is 
undefined for this specific device; for example, 
*XYZ is not defined for any device. 
-114 Header 
suffix out of range 
The value of a numeric suffix attached to a 
program mnemonic, see Syntax and Style 
section 6.2.5.2, makes the header invalid. 
-115 Unexpected 
number of 
parameters 
The number of parameters received does not 
correspond to the number of parameters 
expected. This is typically due an inconsistency 
with the number of instruments in the selected 
group. 
-120 Numeric 
data error 
This error, as well as errors -121 through -129, 
are generated when parsing a data element 
which apprears to be numeric, including the 
nondecimal numeric types. This particular error 
message should be used if the device cannot 
detect a more specific error. 
-121 Invalid 
character in 
number 
An invalid character for the data type being 
parsed was encountered; for example, an alpha 
in a decimal numeric or a “9" in octal data. 
-128 Numeric 
data not allowed 
A legal numeric data element was received, but 
the device does not accept one in this position 
for the header. 
-131 Invalid suffix
The suffix does not follow the syntax described 
in IEEE 488.2, 7.7.3.2, or the suffix is 
inappropriate for this device. 