GW Instek PSW-Series Programming & Command manual User Manual
Page 27

GETTING STARTED
27
Show Version
F-89
0, 1 = PSW version 
2, 3 = PSW build year 
4, 5 = PSW build month/day 
6, 7 = Keyboard CPLD version 
8, 9 = Analog-Control CPLD version 
A, B = Reserved 
C, D = Kernel build year 
E, F = Kernel build month/day 
G, H = Test command version 
I, J = Test command build year 
K, L = Test command build 
 month/day 
M, N
=
USB Driver version.
Power On Configuration Settings*
 
CV Control 
F-90
0 = Panel control (local) 
1 = External voltage control 
2 = External resistance control 
(Ext-R 10kΩ = Vo, max)
3 = External resistance control
(Ext-R
10kΩ = 0)
CC Control
F-91
0 = Panel control (local) 
1 = External voltage control 
2 = External resistance control 
(Ext-R 10kΩ = Io,max)
3 = External resistance control
(Ext-R
10kΩ = 0)
Power-ON Output
F-92
0 = OFF at startup 
1 = ON at startup 
T001 ~ T010 = Run test script TXX at 
start up 
Master/Slave
F-93
0 = Master/Local 
1 = Master/Parallel1 
2 = Master/Parallel2 
3 = Slave/Parallel 
4 = Slave/Series (Only 30V, 80V, 160V 
models) 
External Out Logic
F-94
0 = High ON, 1 = Low ON
Power Switch trip
F-95
0 = Enable , 1 = Disable
Calibration Settings* 
Calibration
F-00
0000 ~ 9999