beautypg.com

Error messages & messages, Led display format – GW Instek PSW-Series Programming & Command manual User Manual

Page 117

background image

APPENDIX

117

Error Messages & Messages

The following error messages or messages may appear on the PSW
screen during operation.

Error Messages

Description

Err 001

USB Mass Storage is not present

Err 002

No (such)file in USB mass storage

Err 003

Empty memory location

Err 004

File access error

Err 901

Keyboard CPLD error

Err 902

Analog CPLD error

Err 920

The ADC is over range for calibration

Err 921

The DAC is over range for calibration

Err 922

Point invalid for calibration

Messages

Description

MSG 001

External control of output. Output off (F-94=0,
High=on)

MSG 002

External control of output. Output off (F-94=1,
Low=on)

MSG 003

F-93 is not zero. Unable to calibrate.

LOCK F-19

F-19 is not zero. Unable to turn the output on.

LED Display Format

Use the following table to read the LED display messages.

0

1

2

3

4

5

6

7

8

9

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

R

S

T

U

V

W

X

Y

Z

(

)

+

-

,