:trigger:pulse:mode 1

Sets the triggering
condition to “>”.

:TRIGger:PULSe:TIMe

Set

Query

Description

Select the time value for pulse width. The setting
range is from 20ns to 10s.
Same as: Trigger MENU key → F4(When) →
Variable knob. (When trigger mode = pulse)

Syntax

< Long >

< Short >

:trigger:pulse:time
:trig:pulse:time?

:trig:puls:tim
:trig:puls:tim?

Parameter/Return
parameter

Pulse width in seconds

Example

:trigger:pulse:time?
>1.000E+01

The pulse width is 10
seconds.

:TRIGger:REJect

Set

Query

Description

Sets or queries the frequency rejection mode.
Same as: Trigger MENU key →
F5(Slope/Coupling)→F3(Rejection).

Syntax

< Long >

< Short >

:trigger:reject < 0 | 1 | 2 >
:trig:reject?

:trig:rej <0 | 1 | 2 >
:trig:rej?

Parameter/Return
parameter

0

Off

1

Low frequency rejection