beautypg.com

Trigger:frequency, Trigger:level, Trigger:mode – GW Instek GBS-1000 Series Programming Manual User Manual

Page 79

background image

COMMAND SET

79

:TRIGger:FREQuency

Set

Query

Description

Returns the readout value of the trigger frequency
counter.

Syntax

< Long >

< Short >

:trigger:frequency?

:trig:freq?

Return parameter

Frequency in Hz

Example

:trigger:frequency?
> 1.000E+03

Returns the trigger
frequency (1000Hz).

:TRIGger:LEVel

Set

Query

Description

Sets or queries the trigger level.
Same as: Trigger level knob.

Syntax

< Long >

< Short >

:trigger:level
:trig:level?

:trig:lev
:trig:lev?

Parameter/Return
parameter

Trigger level voltage

Example

:trigger:level 0

Sets the trigger level to
0 volts.

:TRIGger:MODe

Set

Query

Description

Sets or queries the trigger mode.
Same as: Trigger MENU key → F3(Mode).

Syntax

< Long >

< Short >

:trigger:mode <0 | 1 | 2 | 3>
:trig:mode?

:trig:mod <0 | 1 | 2 | 3>
:trig:mod?

Parameter/Return
parameter

0

Auto level