28

:CHANnel:OFFSet

Set

Query

Description

Sets or returns the offset level for each channel. The
offset level range is dependent on the vertical scale.

Syntax

< Long >

< Short >

:channel:offset
:channel:offset?

:chan:offs
:chan:offs?

Parameter

Channel

Offset level

1/2/3/4 CH1/2/3/

4

±0.5

–0.5V ~ +0.5V
(2mV/div~50mV/div)

±5.0

–5.0V ~ +5.0V
(100mV/div~500mV/div)

±50.0 –50.0V ~ +50.0V

(1V/div ~ 5V/div)

Example

:channel1:scale 1.00e–2
:channel1:offset 2.00e–2

Set CH1 scale to 10mV
Set CH1 offset to 20mV

:CHANnel:PROBe

Set

Query

Description

Sets or returns the probe attenuation factor.
Same as: Channel key → F4

Syntax

< Long >

< Short >

:channel:probe
:channel:probe?

:chan:prob
:chan:prob?

Parameter

Channel

Probe attenuation factor

1/2/3/4 CH1/2/3/4 0

1x

1

10x

2

100x

Example

:channel1:probe 1

Set CH1 probe to 10x