nStrUctionS
:
1. From the D
iAgnoSticS
screen, select the c
ASh
D
iSPenSer
option by
pressing number <1> on the keypad.
2. From the c
ASh
D
iSPenSer
screen, select the i
nject
n
ew
c
ASSette
iD
option by pressing number <5> on the keypad.
D
eScriPtion
:
The NMD-100 dispensing mechanism use cassettes that possess onboard
memory. This memory enables a cassette to store its own identification (ID)
code.
The i
nject
n
ew
c
ASSette
iD function has no direct correlation to the physi-
cal position of the cassette within the unit. In most instances, the cassette
identified as “A” will be placed in the top feed channel, “B” in the second,
and continuing. This is not a requirement since the ID code allows the dis-
pensing mechanism (and the dispensers central controller) to locate the cas-
sette wherever it’s been placed in the dispenser.
This function allows injecting a new ID into a cassette. Insert the cassette you
want to ID into the top feed channel. Press the button corresponding to the
identity you want the cassette to have: ‘A’, ‘B’, ‘C’, or ‘D’. When the ID has
successfully been injected, a message prompt will appear. If the operation
fails, an error message will appear.