beautypg.com

Caution – Triton FT5000XP Prism NDC Emulation w/XFS Compliance User Manual User Manual

Page 22

background image

18

M

odel

Rl/Ft5000

Xp

U

SeR

M

anUal

w

/p

RiSM

tM

ndc e

MUlation

i

ntRodUction

The purpose of this section of the

manual is to describe the procedures

for: (1) removing and replacing note

cassettes, (2) loading cassettes, and (3)

removing and replacing the reject notes

(as applicable). Information concerning

note handling and quality issues are

explained where appropriate.

d

iSpenSing

M

echaniSM

The RL/FT

XP

-series ATMs use an

NMD-100, friction-feed dispensing

mechanism to store and deliver notes

and other media to the customer. The

mechanism is located in the lower

security container of the unit. It holds

multiple cassettes and a single reject

cassette. The note capacity for the cas-

settes is approximately 2750.

The dispensing mechanism delivers the

appropriate number of notes from the

note cassettes to fulfill the customer’s

withdrawal request. The purpose of the

reject cassette is to accept and hold

notes that have been transferred from

the note cassettes but not dispensed.

Some situations that could cause the

mechanism to reject notes are:

Multiple notes stuck together

Note width too short or long

Notes skewed in feed path

Notes too close together in

feed path

Notes not claimed by customer

(after a preset time out the mecha-

nism will retract the notes and

send them to the reject cassette).

The mechanism is able to reject

single notes or bundles. A bundle

reject occurs when more than one

note is rejected at the same time.

There are two compartments within

the reject cassette to keep notes in

these two categories separated. The

top compartment within the cassette

can hold a maximum of 250 bundle-

notes; the lower compartment can

hold up to 100 single-note rejects.
IMPORTANT! The first time the

dispenser is set up, or if a new note

cassette is installed, the mechanism

will enter a learning mode, during

which it will reject 7-15 notes as it

learns the thickness of the currency

or other media. With multiple cas-

settes installed, the number of test re-

jects could almost fill the single-note

compartment of the reject cassette. In

such cases, it is recommended that

you remove any rejected notes from

the unit before placing the ATM back

into service.

n

ote

c

ondition

The number of rejects can be directly

influenced by the technique used to

load the cassettes and the quality

of the currency. Notes loaded into

the mechanism cassettes must be

in “fit” condition if a high level of

performance (low reject and failure

rate) is expected from the unit. “Fit”

notes are defined as those that do not

possess any of the defects listed here:

**CAUTION**

d o n o t R e c Y c l e

ReJected noteS into a

caSSette!

Doing so could cause more

rejects and/or currency jams.

This manual is related to the following products: