t
riton
D
iAgnoSticS
73
t
eSt
D
iSPenSe
A
cceSS
i
nStrUctionS
:
1. From the D
iAgnoSticS
screen, select the c
ASh
D
iSPenSer
option by
pressing number <1> on the keypad.
2. From the c
ASh
D
iSPenSer
screen, select the t
eSt
D
iSPenSe
option by
pressing number <3> on the keypad.
D
eScriPtion
:
The t
eSt
D
iSPenSe
command allows the user to dispense note(s) from each
installed and operational cassette into the reject cassette. This test exercises
the dispenser mechanism without sending notes to the exit.
The l
ock
A
ll
c
ASSetteS
function will automatically be performed first to
ensure that all cassettes are locked. Next, the cassettes’ information will be
retrieved. The Test Dispense can only be exercised on the cassettes installed.
Once the cassette information is retrieved, the user will be prompted to enter
the number of note(s) to be dispensed from cassette A through D, if applica-
ble. The values for the number of notes are 1 to 5. If the user enters a number
greater than 5, it will automatically default to 5.
Press the number <1> on the keypad and enter the desired value. Press the
<Enter> key. Repeat for the remaining cassettes that are available.
Next, press the number <5> on the keypad to P
erForm
t
eSt
. The dispenser
will dispense the note(s) from the cassette(s) into the reject cassette. The
progress bar will be displayed while the operation is being performed.
When the test is completed, the user will be prompted to either perform an-
other test or exit and go back to the Cash Dispenser menu.