2 parameter control code chart, 3 display and error messages – Rice Lake Condec UMC600 User Manual
Page 70

Appendix
67
9.2
Parameter Control Code Chart
Use the following code values for parameter descriptions listed in Table 9-2 when specifying the format string. The
actual character depends on the character mapping used by the output device.
Table 9-2. Parameter Control Code Chart
9.3
Display and Error Messages
Code
Description
Code
Description
Code
Description
200
Gross weight & LB/KG GR
240
Truck gross lb/kg GR
600
Macro file 1 (7.9)
201
Gross weight & LG/KG
241
Truck gross only
601
Macro file 2 (7.10)
202
Gross weight
242
Truck tare lb/kg TR
↕
↕ (7.11 – 7.15)
203
Gross weight (no 0 blanking)
243
Truck tare only
607
Macro file 8 (7.16)
244
Truck net lb/kg NT
210
Net weight & LB/KG NT
245
Truck net only
700
Delay per setup
211
Net weight & LN/KN
800
Setpoint 1 & SP1 data
212
Net weight
300
Status character
801
SP1 data only
213
Net weight (no 0 blanking)
400
Time & date per setup
802
Setpoint 2 & SP2 data
401
Time per setup
803
SP2 data only
220
Tare weight & LB/KG TR
402
Date per setup
221
Tare weight & LT/KT
500
Ident no. & ID. NO.
999
End of file
222
Tare weight
501
Ident no. only
223
Tare weight (no 0 blanking)
502
Tag
503
held ID NO. & ID. NO.
230
Total WEIGHT & lb/kg TOTAL
504
Held ID NO. (no label)
231
Total weight & LA/KA
510
TICKET NO. & counter data
232
Total weight only
511
Counter data only
233
Total weight (no 0 blanking)
Display Messages
Display
Explanation
Corrective Action
Err 1
Err 1a, 1b, 1c
Loss of configuration
Loss of option configuration
Enter configuration
Enter option mode reconfigure
Err 2
Loss of zero calibration
Enter digital calibration mode and recalibrate unit
Err 3
Loss of span calibration
Err 5
Loss of auto tare
Acquire tare
Err 6
Loss of auto zero
Acquire zero
Err 9
Not in span calibration
Program in desired value before entering
Err 10H
Err 10L
Input > 3.3mV/V @ full scale
Input < 0.4mV/V @ full scale
Recalibrate span so FS ≤ 3.3mV/V
Recalibrate span so FS ≥ 0.4mV/V
Err 10P
Err 10-
PTZ (push to zero) > 2.0%
PTZ > weight used for span calibration
Perform zero calibration
CAL
Indicates successful calibration
OL
Gross overload
Check load cell wiring
UL
Gross underrange
Table 9-3. Display and Error Messages