10 option 10 – setpoints, 11 option 11 – remote input option – Rice Lake Condec UMC600 User Manual
Page 43

40
UMC600 Installation Manual
4.10 Option 10 – Setpoints
This option allows an active setpoint to be operated using the display, gross, or net data. When option 10 is turned
on the selection of data that setpoint 1 operates off of is configured in 10.1 and 10.2 for setpoint 2.
Table 4-19 shows the option 10 parameters.
Table 4-19. Option 10 Parameters
For additional information on setpoints refer to Section 7 on page 55.
Refer to Section 4.12.3 on page 46 for individual serial command option parameters for Option 10.
4.11 Option 11 – Remote Input Option
The remote input option provides a means of connecting remote inputs to the indicator and option 11 is used to
configure those digital inputs to something other than to the defaults.
Table 4-20 shows the option 11 parameters.
Selecting any of these options, 11.1 - 11.5 enables the user to access the data selection for each of the inputs 1-5.
Refer to Section 4.12.3 on page 46 for individual serial command option parameters for Option 11.
Option
Prompt Display
Interpretation
Interpretation
All Off
--------
Mode not enabled (options one through ten turned off)
OP.10
OP.10 oFF
OP.10 on
Off
On – setpoint option enabled
10.1 dSP
Gr
net
Setpoint 1 uses display data
Setpoint 1 uses gross weight data
Setpoint 1 uses net weight data
10.2 dSP
Gr
net
Setpoint 2 uses display data
Setpoint 2 uses gross weight data
Setpoint 2 uses net weight data
10.3 oFF
Gr
net
Either mode
Batching while in gross display mode
Batching while in net display mode
Control the Batch 1 start
mode
10.4 oFF
(0 - 50)
No zero restriction to start the batch.
+/- 1 display grad band
Control the Batch 1 start
zero band
Option
Prompt Display
Interpretation
Off
------- Mode not enabled
OP.11
OP.11 oFF
OP.11 On
Off - remote input option disabled
On - remote input option enabled
Default Settings
Normal Batch
11.1 Input 1 (TB3-10)
Data Selection for all:
Zer Zero Scale
n-G Net/Gross toggle
tar Auto Tare
Prt Print
Sta Batch Start
Pau Batch Pause
Abo Batch Abort
11.2 Input 2 (TB3-9)
Tare
Start Batch
11.3 Input 3 (TB3-8)
Abort
Zero
11.4 Input 4 (TB3-7)
Net/Gr
Abort
11.5 Input 5 (TB4-5)
Table 4-20. Option 11 Parameters