Configuration
13
3.0
Configuration
Prior to calibration, the UMC600 must be digitally
configured, or assigned a set of operating parameters.
The three parameters listed in Section 3.1.1 are directly
related to calibration and must be set before proceeding
to calibration mode.
3.1
Digital Configuration
3.1.1
Parameter Overview
Table 3-1 on page 14 lists configuration parameters and
describes their values. The following paragraphs give
the procedure for configuring the UMC600.
3.1.2
Configuration Procedure
1. Unscrew the two screws on the face plate
bracket (Figure 3-1). The bracket drops down,
exposing four program switches on the left side
of the indicator.
Figure 3-1. Accessing the Program Switches
2. Temporarily remove the unit’s flexible black
display overlay by gently pushing down and
lifting the panel up and out at its center to expose
the configuration and calibration instructions
printed on the surface below. The switch
function table defines the appropriate front panel
switch settings for the
CONF
and
CAL
modes.
3. Close switch SW1-2, marked
CONF
(2), by
moving to the up position (see Figure 3-2). A
prompt appears with a parameter number and
data value.
The parameter identifier is a number, 1–14, that
correlates to the
CONFIG
chart on the upper left of the
switch map panel. Selected data represents the value
being entered into the unit configuration data. For
example, 1 100 sets the indicator to 10,000 graduations
(see Table 3-2 on page 16).
When configuration is complete, set SW1-2 down to
return the unit to normal operating mode.
Figure 3-2. Closing Switch 2
Figure 3-3 defines the functional operation of each key
on the front panel of the indicator when the unit is in the
the setup mode.
Figure 3-3. Front Panel Key Functions
NOTE: The TARE RECALL key functions as a previous
screen key in CONFIG mode.
1
6
2
7
3
8
4
9
5
0
CE
ENT
TARE
RECALL
NET
GROSS
TARE
lb/kg
CONV
1 SET
POINT
2 SET
POINT
CAPACITY
5000 lb. X 0.5
ZERO
NET
GROSS
lb
kg
MOTION
ZERO
3 4
2
1
OPEN
Zero
Net/Gross
Tare
Units
Parameter
Select
Parameter Data
Select
Subparameter
Select
Subparameter
Data Select
DEAD LOAD (3)
CONF (2)
CAL (1)
3 4
2
1
OPEN
NORM
1
6
2
7
3
8
4
9
5
0
CE
ENT
TARE
RECALL
NET
GROSS
TARE
lb/kg
CONV
1 SET
POINT
2 SET
POINT
CAPACITY
5000 lb. X 0.5
ZERO
NET
GROSS
lb
kg
MOTION
ZERO
Parameter
Identifier
Selected Data
ZERO
NET
GROSS
TARE
lb/kg
CONV