2 macro file setup – Rice Lake Condec UMC600 User Manual
Page 38

Options Configuration
35
4.7.2
Macro File Setup
There may be times when you need to print more than the 30 character codes that are allowed in the custom transmit
files (7.1 - 7.8). To do custom transmits larger than 30 character codes, the UMC600 provides eight “macro” files
(7.9 to 7.16) that can be called in from the custom transmit files. This is done by putting a parameter code of 600,
601, 602, 603, 604, 605, 606, or 607 in your custom transmit file to macros 7.9 through 7.16 respectively. As with
the custom transmit files, each macro file can contain up to 30 character codes. You can call more than one macro in
your custom transmit or even call the same macro more than once.
Each macro file holds up to 30 ASCII characters and parameter codes. Refer to the ASCII characters and Table 9-2
in Section 9 for parameter codes.
Table 4-11. Print File Definition Codes
Table 4-12. Code 600 Definitions
Table 4-13. Code 601 Definitions
Print File 7.1 – Port 1 gross mode data
Line #
Code
Code definition
01
002
STX start of text
02
600
* macro file #1 (7.9)
03
200
gross weight with lb/kg gr
04
032
SP (space)
05
601
* macro file #2 (7.10)
06
013
CR (carriage return)
07
010
LF (line feed)
08
999
end of file
Code 600 – macro file 7.9
Line #
Code
Code definition
01
065
A character
02
067
C character
03
032
SP (space)
04
105
i character
05
110
n character
06
099
c character
07
046
. (period)
08
013
CR (carriage return)
09
010
LF (line feed)
10
999
end of file
Code 601 – macro file 7.10
Line #
Code
Code definition
01
402
date per setup
02
032
SP (space)
03
401
time per setup
04
999
end of file