UMC600 Installation Manual
3.2
Serial Configuration
The UMC600 has two serial ports. Both serial ports 1 and 2 are ASCII-compatible, 20 mA current loop, or RS-232
outputs. The serial format is compatible with most printers, scoreboards, and other remote devices. Each output can
be disabled, set for print on demand mode, or set to output data continuously.
Table 3-8 shows the configuration selections for parameter 14, which control the configuration of ports 1 and 2.
Note: Settings for simplex (14.S1) and duplex (14.dU) are the same except that ports 1 and 2 must have the same
baud rate when in duplex mode.
Parameter
Subparameter
Selection
Subparmeter Data
Selection
Explanation
Net/Gross
Tare
Lb/Kg Conversion
Key which affects associated parameters
14.
oFF
Serial communications disabled
14.
SI
Port 1 and 2: simplex
14.1
Demand print configuration in net mode
14.1Gtn
14.1nEt
Three-line output G-N-T
Single line, net print
14.2
Delay after carriage return (CR) enable
14.2oFF
14.2 1
14.2 2
14.2 3
14.2 4
No delay after CR
1 second delay after CR
2 seconds delay after CR
3 second delay after CR
4 second delay after CR
14.3
Port 1 configuration
14.3oFF
14.3 Co
14.3 dE
Port 1 disabled
Continuous output
Demand print
14.4
Port 1 baud rate
14.4 3
14.4 6
14.4 12
14.4 24
14.4 48
14.4 96
300 bps
600 bps
1200 bps
2400 bps
4800 bps
9600 bps
14.5
Port 2 configuration
14.5oFF
14.5 Co
14.5 dE
Port 2 disabled
Continuous output
Demand print
14.6
Port 2 baud rate
14.6 3
14.6 6
14.6 12
14.6 24
14.6 48
14.6 96
300 bps
600 bps
1200 bps
2400 bps
4800 bps
9600 bps
Table 3-8. Parameter 14 Configuration Parameters