beautypg.com

Index – Yokogawa Value Series FX1000 User Manual

Page 50

background image

2-37

IM 04L21B01-64EN

Configuring the FX1000

1

2

3

8

Index

Option

• Value on Error

Specify whether to set the display for a computation error to [+Over] or [–Over].

• Overflow Sum, Ave

Specify how to handle overflow data when it is detected in the SUM or AVE

computation of TLOG or CLOG. This setting is also applied to report generation.

Settings

Description

Error

Sets the computed result to computation error.

Skip

Discards the overflow data and continues the computation.

Limit

Uses a limit value in place of the overflow data and continues the computation.

• Overflow Min, Max, P-P

Specify how to handle overflow data when it is detected in the MAX, MIN, or P-P

computation of TLOG or CLOG. This setting is also applied to report generation.

Settings

Description

Over

Uses the overflow data as-is.

Skip

Discards the overflow data and continues the computation.

• Report (1 to 4)

Select the type of data to output as reports.

Settings

Description

OFF

Does not output reports. You cannot set Report 1 to [OFF].

Ave

Outputs the average value.

Max

Outputs the maximum value.

Min

Outputs the minimum value.

Sum

Outputs the sum value.

Instant

Outputs the instantaneous value.

• File kind

Specify the method used to create report files.

Settings

Description

Split

Saves each type of report to a separate file.

Combined

Saves the report data of two types in a single file.

2.6 Entering Basic Settings