6 entering basic settings, Environment, 6 entering basic settings -33 – Yokogawa Value Series FX1000 User Manual
Page 46: Environment -33, Index
2-33
IM 04L21B01-64EN
Configuring the FX1000
1
2
3
8
Index
2.6 Entering Basic Settings
The items that you can configure vary depending on the system configuration and the
settings.
Environment
Basic Environment
• Data Kind
Settings
Description
Display
Records display data.
E+D
Records display data and event data. You cannot select [E+D] when [Trend
Rate Switching] under [Environment] - [Detail Setting] under the [Basic
setting] tab is set to [ON].
Event
Records event data.
• Temperature Unit
Select C or F.
• Time zone
Set the time zone of the region in which the FX will be used in terms of the time
difference from GMT.
• Time deviation limit
Time deviation limit
Current time
Specified time
When the time deviation between the time on the FX and the specified time is within
±(the value specified here), the time on the FX is gradually corrected. Otherwise, the
clock is corrected immediately.
Select from 10 s to 5 min. Select [OFF] to disables the function.
Example: If [Time deviation limit] is set to 10s and the time on the FX is 10 hours 21 minutes
15 seconds, the time on the FX is gradually corrected if the specified time is between
10 hours 21 minutes 5 seconds and 10 hours 21 minutes 25 seconds.