Troubleshooting, Vi. error codes 6.1 e – Yokogawa digitalYEWFLO (DY) User Manual
Page 93

IM 1F2B4-01-YIA
Page 88
TROUBLESHOOTING
VI.
ERROR CODES
6.1
E
RROR
C
ODE
L
ISTING
Effect on Output
Effect on Indication via local Digital Display
Error
No.
Diagnostic
Message
Error definition and
Probability Cause
Current
Output
Pulse Output
Rate in %
Output
Rate in
Engineering
Units
Totalizer
Corrective Action
1
Over
Output
This error signifies that the
flow exceeds the meter span
by over 110%.
Output driven
to a fixed
110%.
Normal
Operation
Indication is
driven to a
fixed 110% of
the span.
Normal
Operation
Normal
Operation
Respan the meter or
correct the overrange
condition.
2
Span Set
error
A span setting error
indicates that the span
velocity limits have been
exceeded. (32 ft/sec for
liquids and 262 ft/sec for
gas). Sensor may be
damaged. Contact
Yokogawa Industrial
Automation service
department for analysis.
Output may be
non-linear.
Output may be
non-linear.
Output may be
non-linear.
Output may be
non-linear.
Output may be
non-linear.
Correct the span
setting in parameter
B51 and B52 to meet
the velocity
limitations of the
meter.
3
NJ circuit
error
Noise discrimination circuit
is not functioning properly.
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Amplifier replacement
required. Contact
Yokogawa Industrial
Automation service
dept.
4
Pulse Out
error
The pulse output span has
exceeded 6K Hertz.
Normal
Operation
Output is
limited to 6K
Hertz.
Normal
Operation
Normal
Operation
Normal
Operation
Check parameter
settings, in particular
C02.
5
EE Prom
error
EE prom is not functioning
correctly.
Output is fixed
at 1.25%.
No output
Output is fixed
at -1.25%.
Output is fixed
at 0.0%.
No output
Amplifier replacement
required. Contact
Yokogawa Industrial
Automation service
dept.
---
CPU error
The CPU has failed and the
meter is not functioning.
The display and self-
diagnostics are completely
inoperable.
Output is fixed
at 1.25%.
No output
No output
No output
No output
Amplifier replacement
required. Contact
Yokogawa Industrial
Automation service
dept.