beautypg.com

Maintenance – Yokogawa digitalYEWFLO (DY) User Manual

Page 69

background image

MAINTENANCE

IM 1F2B4-01-YIA

Page 73

milliAmp example:
Calculate the new settings using X and Y values from above:

(Equation 1)
NEW H08 setting = ( 4 - X ) / ( Y - X ) * 100 + orig. H08 setting

example: 0.89 = ( 4 - 3.93 )/( 19.72 - 3.93 ) * 100 + 0.45

Example: milliAmp

Original

New

H08

.45

.89

H09

1.25

2.58

X

3.93 mA

4.00 mA

Y

19.72 mA

20.00 mA

(Equation 2)

NEW

H09

setting = ( 16 + X - Y )/( Y - X )*100 + current H09 setting

example: 2.58 = ( 16 + 3.93 - 19.72 )/( 19.72 - 3.93 ) * 100 + 1.25

0-100% example:
Calculate the new settings using X and Y values from above, where X and Y have been converted
to % of span values.

Example: 0-100%

Original

New

H08

.45

.89

H09

1.25

2.58

X

-0.43%

0.0%

Y

98.25%

100.0%

(Equation 1)
NEW H08 setting = - X / ( Y - X ) * 100 + orig. H08 setting

example: 0.89 = - ( -0.43 )/( 98.25 - (-0.43)) * 100 + 0.45

(Equation 2)

NEW

H09

setting = ( 100 + X - Y )/( Y - X )*100 + current H09 setting

example: 2.58 = ( 100 + (-0.43) - 98.25 )/( 98.25-(-0.43)) * 100 + 1.25