beautypg.com

Introduction, Table 1.4.3: steam - flowmeter range – Yokogawa digitalYEWFLO (DY) User Manual

Page 12

background image

INTRODUCTION

IM 1F2B4-01-YIA
Page 8

STEAM

Nominal Size Flow Rate

Minimum Linear and Maximum Measurable Saturated Steam Flow Rates in lb/hr

(inches)

Limits

at process line pressure

15 psig

25 psig

50 psig

75 psig

100 psig

125 psig

150 psig

175 psig

200 psig

250 psig

300 psig

½

min

12.8

14.6

18.4

21.5

24.1

26.5

28.7

30.7

32.6

36.6

43.4

max

122

161

254

346

437

527

616

705

765

973

1154

1

min

29.7

34

42.8

49.9

56.1

61.6

66.6

71.3

75.7

83.7

91.2

max

379

498

788

1071

1353

1632

1910

2185

2464

3014

357

min

58.7

67.3

84.6

98.6

118

137

156

173

191

224

257

max

905

1188

1879

2554

3228

3894

4557

5215

5879

7192

8530

2

min

97.5

111

140

164

184

202

219

234

248

298

354

max

1500

1969

3113

4232

5349

6452

7550

8639

9740

11916

14133

3

min

188

216

271

316

355

390

422

452

480

576

683

max

2895

3800

6010

8170

10326

12455

14576

16678

18804

23004

27283

4

min

328

376

472

551

659

766

869

967

1065

1251

1434

max

5054

6633

10490

14260

18023

21739

25440

29109

32820

40150

47620

6

min

719

824

1184

1515

1827

2122

2407

2681

2951

3467

3974

max

11065

14523

22969

31224

39463

47600

55705

63739

71864

87914

104270

8

min

1549

1885

2720

3477

4193

4872

5525

6153

6773

7958

9122

max

19785

25968

41070

55830

70561

85111

99603

113968

128496

157194

186439

10

min

2725

3387

4888

6249

7536

8756

9930

11060

12174

14304

16396

max

30596

40157

63509

86334

109114

131614

154024

176238

198703

243081

288305

12

min

3903

4851

7000

8949

10793

12539

14220

15839

17434

20485

23481

max

43816

57590

90952

123640

156263

188485

220578

252392

284564

348119

412883

Table 1.4.3: Steam - Flowmeter Range

Notes: 1)

Maximum flowrates are based on 262 ft/sec.

2)

These figures are approximations. Refer to the sizing program for the exact minimum and
maximum flowrates for your applications.

Nominal Size Internal Diameter Cross Sectional Nominal Pulse Rate

Nominal K-factor

(inches)

(inches)

Area (ft

2

)

(Hz/ft/s)

Pulse/US gal

Pulse/ft

3

½

0.57

0.0018

19.1

1423

10645

1

1.01

0.0056

10.8

259

1940

1.56

0.133

7.05

70.8

530

2

2.01

0.022

5.59

33.9

253

3

2.8

0.043

4.02

12.6

94.3

4

3.69

0.074

3

5.39

40.3

6

5.46

0.163

2.03

1.67

12.5

8

7.31

0.291

1.52

0.7

5.24

10

9.09

0.45

1.23

0.366

2.74

12

10.9

0.645

1.03

0.213

1.59

Table 1.4.4: Nominal K-factor and general flowmeter information