᭹ AXF Standard, AXF015, Wafer Type, Ceramics Lining
*3: D, E, F, G; Integral Flowmeter,
N, P; Remote Flowtube
*3
AXF015
G
C
D
E
F
G
N
P
1
2
N
C E 1
A
1
015
15(0.5)
C
85(3.35)
44(1.73)
15(0.59)
144(5.67)
268(10.55)
2.3(5.1)
306(12.03)
4(8.8)
Model
Remote
flowtube
Integral
flowmeter
Remote
flowtube
Integral
flowmeter
Max. Height
Hr
Hi
Weight kg (lb)
Max. Height
Weight kg (lb)
Height
H1
Size code
Size
Lining code
Face-to-face
length
L
*
2
Outside dia.
D
Inner diameter of
Grounding ring
ød
F26.EPS
*1: When indicator code N is selected, subtract 12 mm
(0.47 inch) from the value in the figure.
In case of explosion proof type with indicator, add 5 mm
(0.2 inch) to it.
*2: Depending on the selection of grounding ring code and
optional code, add the following value to L (face-to-face
length).
Grounding Ring Code S, L, H, V
P, T
N
L(Face-to-face length)
+0
+22(087) -6(0.24)
Unit : mm (approx. inch)
Remote Flowtube
Integral Flowmeter
Remote Flowtube
Integral Flowmeter
* No infra-red switches are furnished
for Fieldbus communication type.
Hi
49(1.93)
73
(2.87)
Hr
H1
63.5(2.50)
3(0.12)
ø86(3.38)
48
L*
2
Ground Terminal
(M4)
Ground Terminal
(M4)
ø128(5.04)
197(7.76)*
1
154(6.06)
111(4.37)
28(1.1)
66*
1
(2.6)
51.5
(2.03)
51.5
(2.03)
(1.89)
70(2.76)
ᮀ72
ᮀ58
D
(шd)
(2.83)
(2.28)
4- ш6.2(0.24)
᭹ AXF Standard, AXF025-AXF100, Wafer Type, Ceramics Lining
Unit : mm (approx. inch)
Remote Flowtube
Integral Flowmeter
Remote Flowtube
Integral Flowmeter
73(2.87)
H1
Hr
L*
2
154(6.06)
Hi
49(1.93)
28(1.1)
ø128(5.04)
(M4)
(M4)
Ground Terminal
111(4.37)
197(7.76)*
1
66*
1
(2.6)
51.5
(2.03)
51.5
(2.03)
ø86(3.38)
48(1.89)
70(2.76)
(ød)
øD
Ground Terminal
*1: When indicator code N is selected, subtract 12 mm (0.47
inch) from the value in the figure.
In case of explosion proof type with indicator, add 5 mm
(0.2 inch) to it.
*2: Depending on the selection of grounding ring code and
optional code, add the following value to L (face-to-face
length).
F27.EPS
Grounding Ring Code S, L, H, V
P, T
N
L(Face-to-face length)
+0
+22(0.87) -6(0.24)
AXF025
AXF040
AXF050
AXF080
AXF100
G
C
D
E
F
G
N
P
1
2
N
C E 1
A
1
*3: D, E, F, G; Integral Flowmeter,
N, P; Remote Flowtube
*3
025
25(1)
C
93(3.66)
67.5(2.66)
27(1.06)
92(3.62)
216(8.50)
2.3(5.1)
254(9.98)
040
40(1.5)
C
106(4.17)
86(3.39)
40(1.57)
111(4.37)
235(9.25)
3.2(7.0)
273(10.73)
050
50(2)
C
120(4.72)
99(3.90)
52(2.05)
129(5.08)
253(9.96)
4.1(9.0)
291(11.44)
080
80(3)
C
160(6.30)
129(5.08)
81(3.19)
159(6.26)
283(11.14)
6.8(15.0)
321(12.64)
100
100(4)
C
180(7.09)
155(6.10)
98(3.86)
184(7.24)
308(12.13)
9.6(21.1)
346(13.62)
Max. Height
Hr
Hi
Weight kg (lb)
Max. Height
Weight kg (lb)
Height
H1
Size code
Size
Lining code
Face-to-face
length
Outside dia.
ø
D
Inner diameter of
Grounding ring
ø
d
Model
Remote
Flowtube
Integral
Flowmeter
Remote
Flowtube
Integral
Flowmeter
4.0(8.8)
5.8(12.7) 8.5(18.8) 11.3(24.9)
4.9(10.8)
L
*
2
* No infra-red switches are furnished