5 tiis, Tiis -8, 3) operation (integral flowmeter) – Yokogawa ADMAG AXF User Manual
Page 124: Integral flowmeter)

IM 01E20D01-01E
8-8
8. EXPLOSION PROTECTED TYPE INSTRUMENT
(3) Operation
(Integral Flowmeter)
WARNING
• After de-energizing, delay 20 minutes before
opening.
• Take care not to generate mechanical spark
when access to the instrument and peripheral
devices in hazardous locations.
(Remote Flowtube)
WARNING
• De-energize before opening.
• Take care not to generate mechanical spark
when access to the instrument and peripheral
devices in hazardous locations.
(4) Maintenance and Repair
WARNING
The instrument modification or parts replacement
by other than authorized representative of
Yokogawa Electric Corporation is prohibited and
will void the certification.
8.5 TIIS
CAUTION
The model AXF
ٗٗٗC magnetic flowmeter with
optional code JF3, which has obtained
certification according to technical criteria for
explosion-protected construction of electric
machinery and equipment (Standards
Notification No. 556 from the Japanese Ministry
of Labor) conforming to IEC standards, is
designed for hazardous areas where
inflammable gases or vapors may be present.
(This allows installation in Division 1 and 2
areas)
To preserve the safety of flameproof equipment
requires great care during mounting, wiring, and
piping. Safety requirements also place
restrictions on maintenance and repair activities.
Users absolutely must read “INSTALLATION
AND OPERATING PRECAUTIONS FOR TIIS
FLAMEPROOF EQUIPMENT” at the end of this
manual.
(1) Technical Data
Certificate:
Wafer Type;
T33-1.EPS
Ceramics
Lining
Ceramics
Lining
PFA
Lining
PFA
Lining
-A**
-A**
-A**
-A**
Integral Flowmeter
Remote Flowtube
Lining / Process
Connection
code
Size: mm
(inch)
2.5 (0.1)
5 (0.2)
10 (0.4)
15 (0.5)
25 (1.0)
(Lay length code 1)
25 (1.0)
(Lay length code 2)
32 (1.25)
40 (1.5)
50 (2.0)
65 (2.5)
80 (3.0)
100 (4.0)
125 (5.0)
150 (6.0)
200 (8.0)
250 (10)
300 (12)
350 (14)
400 (16)
TC18966
TC18966
TC18966
TC18966
TC16631
TC18967
TC16632
TC16633
TC16634
TC16635
TC16636
TC16637
TC16638
TC18968
TC18970
TC18972
TC18974
—
—
TC16645
TC16645
TC16645
TC16646
TC16647
—
—
TC16648
TC16649
—
TC18978
TC18979
—
TC18980
TC18981
—
—
—
—
TC18982
TC18982
TC18982
TC18982
TC16655
TC18983
TC16656
TC16657
TC16658
TC16659
TC16660
TC16661
TC16662
TC18984
TC18986
TC18988
TC18990
—
—
TC16669
TC16669
TC16669
TC16670
TC16671
—
—
TC16672
TC16673
—
TC18994
TC18995
—
TC18996
TC18997
—
—
—
—
Flange Type (PFA lining only);
T33-2.EPS
PFA
Lining
PFA
Lining
-B**, -D
-B**, -D**
Integral Flowmeter Remote Flowtube
Lining / Process
Connection
code
Size: mm
(inch)
2.5 (0.1)
5 (0.2)
10 (0.4)
15 (0.5)
25 (1.0)
32 (1.25)
40 (1.5)
50 (2.0)
65 (2.5)
80 (3.0)
100 (4.0)
125 (5.0)
150 (6.0)
200 (8.0)
250 (10)
300 (12)
350 (14)
400 (16)
TC18966
TC18966
TC18966
TC18966
TC16631
TC16632
TC16633
TC16634
TC16635
TC16636
TC16637
TC16638
TC18969
TC18971
TC18973
TC18975
TC18976
TC18977
TC18982
TC18982
TC18982
TC18982
TC16655
TC16656
TC16657
TC16658
TC16659
TC16660
TC16661
TC16662
TC18985
TC18987
TC18989
TC18991
TC18992
TC18993
(Integral Flowmeter)
• Construction: Ex de[ia] IIC T4
: Converter ; Explosion proof
Flowtube ; Increased Safety and
Intrinsically Safety(ia)
Electrode ; Intrinsically Safety(ia)
Um=250VAC 50/60Hz, 250VDC,