Optional specifications for flowtubes – Yokogawa ADMAG AXF User Manual
Page 91

IM 01E20D01-01E
6-29
6. OUTLINE
■ OPTIONAL SPECIFICATIONS FOR FLOWTUBES
᭹ Table of Optional Specifications (Size 2.5 mm (0.1 in.) to 400 mm (16 in.)) “᭛”
T26-1.EPS
3
Code
Submersible
Sanitary
Applicable Model
Remote
Flowtube
Integral
Flowmeter
Remote
Flowtube
Remote
Flowtube
Integral
Flowmeter
Remote
Flowtube
Integral
Flowmeter
General
Item
Specifications
For District
Heating and
Cooling or
Condensation-proof
Urethane resin potting is applied in the terminal box of a remote flowtube.
Select JIS G1/2 for the electrical connections. 30-meter signal and excitation
cables are pre-wired and waterproof grands with union joints are attached at
factory.
–
᭺
–
–
–
–
᭺
DHC
User-specified
Signal and Excitation
Cable Length
Burn Out Down
Lightning Protector
DC Noise Cut Circuit
A lightning protector is built into the power terminals.
The output level is set to 0 mA during a CPU failure and is set 2.4 mA (-10 %)
or less during an alarm. Standard products are delivered with a setting 25 mA
during a CPU failure and 21.6 mA (110%) or more during an alarm.
Available for the submersible type and a model with optional code DHC. The
cable length is limited up to 200 meters when combined with an AXFA11
converter, or 100 meters when combined with an AXFA14 converter.
Following “L,” specify the cable length in three digits as a multiple of 1 meter
(e.g., 001, 002, or 005) for a length up to 5 meters or as a multiple of 5
meters (i.e., 005, 010, 015, or the like) for a length of 5 meters or more. If this
optional code is not selected, a 30-meter length cable is attached.
The DC Noise Cut Circuit is built in. Available for 15 mm (0.5 in.) and larger
sizes, and for fluids with the conductivity of 50
µS/cm or higher. Nullifies the
empty check and electrode adhesion diagnostic function.
NAMUR NE43
Compliance
Output signal
limits: 3.8 to
20.5 mA
Failure alarm down-scale: The output level is set to 0 mA during a
CPU failure and is set 2.4 mA (–10%) or less during an alarm.
Failure alarm up-scale: The output level is set to 25 mA during a
CPU failure and is set 21.6 mA (110%) or more during an alarm.
Active Pulse Output
Mass Unit Setting
Active pulses are output in order to drive an external electromagnetic or
electronic counter directly using the converter’s internal power supply.
(Nullifies the standard transistor contact pulse output.)
Output voltage: 24 V DC
±20%
Pulse specifications:
• The drive current of 150 mA or less
• Pulse rate: 0.0001 to 2 pps (pulse/second); Pulse width: 20, 33, 50, or
100 ms
The flow rate span, transmission pulse weight, and totalizer display pulse
weight can be set in terms of mass unit. Specify the density of the process
fluid when ordering in addition to the mass flow rate span, transmission pulse
wight (for mass unit), and totalizer display pulse weight (for mass unit).
When ordering a remote flowtube, parameters for 'Mass Unit Setting' will be
set in the corresponding converter before shipment.
1. Density
a. Available density Numerics:
Specify the numeric within the value of 500 to 2000 kg/m
3
, 4.2 to
16.7 lb/gal, or 31.2 to 124.8 lb/cf. And it can be up to five digits, to a
maximum of 32000 ignoring the decimal point. A fraction is limited to
the fourth decimal place.
b. Available density units: kg/m
3
, lb/gal, lb/cf
Example: A water density is about 1000kg/m
3
. In this case specify
“1000kg/m
3
”.
However a density is changed by temperature.
Specify the actual density.
(The 1000kg/m
3
is equivalent to 8.345lb/gal and 62.43lb/cf.)
2. The mass flow rate span, transmission pulse weight, and totalizer display
pulse weight
a. Available density Numerics:
Specify the numeric within the value of 0.0001 to 32000. And it can
be up to five digits, to a maximum of 32000 ignoring the decimal
point. A fraction is limited to the fourth decimal place.
b. Mass Units Available mass units: t, kg, g, klb, lb
Available time units: /d, /h, /min, /s
Note1: In case of specifying the mass flow span, calculate the volumetric flow
span by the setting density, and specify the available value in the mass
flow span.
Note2: In case of transmission pulse weight and totalizer display pulse weight,
specify the mass unit which was specified as the flow unit.
–
᭺
–
–
᭺
–
᭺
L***
᭺
–
᭺
–
–
᭺
–
A
᭺ (*10)
–
᭺ (*10)
–
–
᭺ (*10)
–
C1
᭺ (*10)
–
᭺ (*10)
–
–
᭺ (*10)
–
C2
᭺ (*10)
–
᭺ (*10)
–
–
᭺ (*10)
–
C3
᭺ (*10)
–
᭺ (*10)
–
–
᭺ (*10)
–
EM
᭺
–
᭺
–
–
᭺
–
ELC
᭺
᭺
᭺
᭺
᭺
᭺
᭺
MU
᭺: Available
–: Not available
Explosion proof
AXF***G-
D
E
F
G
AXF***G-
N
P
AXF***C-
D
E
F
G
AXF***C-
N
P
AXF***W
-
N
P
AXF***H-
D
E
F
G
AXF***H-
N
P