beautypg.com

Yokogawa ADMAG AXF User Manual

Page 108

background image

IM 01E20D01-01E

6-46

6. OUTLINE

AXF Standard, AXF015-AXF125, Sanitary for Butt Weld, PFA Lining

51.5

(2.03)

(2.03)

51.5

197(7.76)*

1

28(1.1)

66*

1

Hr

48

(1.89)

70(2.76)

154(6.06)

ø86(3.38)

Hi

L

111(4.37)

Ground Terminal

(M4)

(M4)

Ground Terminal

ø1

28(5.04)

F36.EPS

*1: When indicator code N is selected, subtract 12 mm

(0.47 inch) from the value in the figure.

*2: When option code DHC is selected, waterproof

glands and a 30m long cable are attached.
Add 9.5kg (20.9lb) to the weight in the table.

Unit : mm (approx. inch)

Process

Connection

KKB (ISO2037 Butt Weld)

Nominal

Size

15

70

(2.76)

16

(0.63)

18

(0.71)

15.2

(0.60)

30

(1.18)

F9811

NN

25

70

(2.76)

22.2

(0.87)

25.6

(1.01)

22.6

(0.89)

30

(1.18)

F9811

NP

32

70

(2.76)

29.4

(1.16)

34.3

(1.35)

31.3

(1.23)

30

(1.18)

F9811

NQ

40

83

(3.27)

34.6

(1.36)

38.6

(1.52)

35.6

(1.40)

30

(1.18)

F9811

NR

50

96

(3.78)

47.6

(1.87)

51.6

(2.03)

48.6

(1.91)

30

(1.18)

F9811

NS

65

114

(4.49)

59.5

(2.34)

64.1

(2.52)

60.3

(2.37)

30

(1.18)

F9811

NT

80

126

(4.96)

72.3

(2.85)

76.7

(3.02)

72.9

(2.87)

30

(1.18)

F9811

NU

100

152

(5.98)

97

(3.82)

102.5

(4.04)

97.6

(3.84)

30

(1.18)

F9811

NV

125

180

(7.09)

123

(4.84)

141.2

(5.56)

135.7

(5.34)

40

(1.57)

F9811

NW

øA

øB

øC

ød

E

Parts No.

KDB (DIN 1185 Butt Weld)

15

70

(2.76)

16

(0.63)

20

(0.79)

16

(0.63)

30

(1.18)

F9811

ND

25

70

(2.76)

22.2

(0.87)

30

(1.18)

26

(1.02)

30

(1.18)

F9811

NE

32

70

(2.76)

29.4

(1.16)

36

(1.42)

32

(1.26)

30

(1.18)

F9811

NF

40

83

(3.27)

34.6

(1.36)

42

(1.65)

38

(1.50)

30

(1.18)

F9811

NG

50

96

(3.78)

47.6

(1.87)

54

(2.13)

50

(1.97)

30

(1.18)

F9811

NH

65

114

(4.49)

59.5

(2.34)

70

(2.76)

66

(2.60)

30

(1.18)

F9811

NJ

80

126

(4.96)

72.3

(2.85)

85

(3.35)

81

(3.19)

30

(1.18)

F9811

NK

100

152

(5.98)

97

(3.82)

104

(4.09)

100

(3.94)

30

(1.18)

F9811

NL

125

180

(7.09)

123

(4.84)

129

(5.08)

125

(4.92)

40

(1.57)

F9811

NM

H1

(2.6)

Remote Flowtube

Remote Flowtube

Integral Flowmeter

Integral Flowmeter

73(2.87)

49(1.93)

øD

(ød

)

Adapter for butt weld connection

AXF015
AXF025
AXF032
AXF040
AXF050
AXF065
AXF080
AXF100
AXF125

H

D
E

F

G
N

P

1
2

N

A L 1 N

K
K

K
D

B
B

1

Adapter for butt weld connection

*3: D, E, F, G; Integral Flowmeter,

N, P; Remote Flowtube

*3

шA

ш

B

ø

d

ø

C

E

Max. Height

Hr

Hi

Max. Height

Weight kg (lb)

Height

H1

Size code

Process Connection

KKB / KDB

Size

Lining code

Face-to-face

length

L

Outside dia.

Inner dia.

ø

D

ø

d

KDB

KKB

Model

Remote
Flowtube

Integral
Flowmeter

Remote
Flowtube

Integral
Flowmeter

015

15

(0.5)

A

126

(4.98)

73

(2.87)

15.2

(0.60)

16

(0.63)

98

(3.86)

222

(8.74)

2.6

(5.7)

260

(10.24)

4.3

(9.5)

025

25

(1)

A

126

(4.98)

73

(2.87)

22.6

(0.89)

26

(1.02)

98

(3.86)

222

(8.74)

2.3

(5.1)

260

(10.24)

4

(8.8)

032

32

(1.3)

A

126

(4.98)

73

(2.87)

31.3

(1.23)

32

(1.26)

98

(3.86)

222

(8.74)

2.5

(5.5)

260

(10.24)

4.2

(9.3)

040

40

(1.5)

A

126

(4.98)

86

(3.39)

35.6

(1.40)

38

(1.50)

111

(4.37)

235

(9.25)

2.8

(6.2)

273

(10.73)

4.5

(9.9)

050

50

(2)

A

136

(5.37)

99

(3.90)

48.6

(1.91)

50

(1.97)

129

(5.08)

253

(9.96)

3.4

(7.5)

291

(11.44)

5.1

(11.2)

065

65

(2.6)

A

156

(6.16)

117

(4.61)

60.3

(2.37)

66

(2.60)

147

(5.79)

271

(10.67)

4.5

(9.9)

309

(12.17)

6.2

(13.7)

080

80

(3)

A

176

(6.94)

129

(5.08)

72.9

(2.87)

81

(3.19)

157

(6.18)

281

(11.06)

5.3

(11.7)

319

(12.54)

7

(15.4)

100

100

(4)

A

206

(8.13)

155

(6.10)

97.6

(3.84)

100

(3.94)

183

(7.20)

307

(12.09)

7.1

(15.7)

345

(13.56)

8.8

(19.4)

125

125

(5)

A

276

(10.88)

183

(7.20)

135.7

(5.34)

125

(4.92)

212

(8.35)

336

(13.23)

11

(24.3)

374

(14.70)

12.7

(28.0)

*

2

Weight kg (lb)