beautypg.com

Axf standard (clamp/union/butt weld connection) – Yokogawa ADMAG AXF User Manual

Page 86

background image

IM 01E20D01-01E

6-24

6. OUTLINE

AXF STANDARD (Clamp/Union/Butt Weld Connection)

Sanitary Type , PFA Lining

Use

Converter

Output Signal

and

Communication

Power Supply

Lining (*4)

Electrode Material (*4)

Sanitary Type

Integral Flowmeter with 4 to 20 mA DC Output and BRAIN Communication

Integral Flowmeter with 4 to 20 mA DC Output and HART Communication

Integral Flowmeter with Digital communication

(F

OUNDATION

Fieldbus protocol) (*5)

Integral Flowmeter with Digital communication

(PROFIBUS PA protocol) (*6)

Remote Flowtube for Combined use with AXFA11

Remote Flowtube for Combined use with AXFA14

Integral Flowmeter, 100 V to 240 V AC or 100 to 120 V DC

Integral Flowmeter, 24 V AC/DC

Remote Flowtube

JIS SUS316L (AISI 316L SS/EN 1.4404 Equivalent)

Non-replaceable

None

-D · · · · · · · · · · · · · · · · ·

-E · · · · · · · · · · · · · · · · ·

-F · · · · · · · · · · · · · · · · ·

-G · · · · · · · · · · · · · · · · ·

-N · · · · · · · · · · · · · · · · ·

-P · · · · · · · · · · · · · · · · ·

Fluorocarbon PFA

Grounding Ring

Process Connection

(*2) (*4) (*7)

Size 15 mm (0.5 in.) to 100 mm (4.0in.),

except 32 mm (1.25 in.)

Size 15 mm (0.5 in.) to 125 mm (5.0 in.)

Size 15 mm (0.5 in.) to 125 mm (5.0 in.)

Size 15 mm (0.5 in.) to 125 mm (5.0 in.)

Size 15 mm (0.5 in.) to 100 mm (4.0 in.)

Size 25 mm (1.0 in.) to 100 mm (4.0 in.)

Size 15 mm (0.5 in.) to 125 mm (5.0 in.)

Size 15 mm (0.5 in.) to 125 mm (5.0 in.)

Electrode Structure

-HAB · · · · · ·

-HDB · · · · · ·

-HKB · · · · · ·

-JDB

· · · · · ·

-JKB

· · · · · ·

-JSB

· · · · · ·

-KDB · · · · · ·

-KKB · · · · · ·

N · · · · · · · · · · · ·

1· · · · · · · · · · · · · ·

L

· · · · · · · · · · · · ·

1 · · · · · · · · · · · · · · · ·

2 · · · · · · · · · · · · · · · ·

N · · · · · · · · · · · · · · · ·

A

· · · · · · · · · · · · · ·

H · · · · · · · · · · · · · · · · · · · ·

Model

Suffix Code

Description

Applicable Model

AXF015

AXF025

AXF032

AXF040

AXF050

AXF065

AXF080

AXF100

AXF125

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

· · · · · · · · · · · · · · · · · · · ·

Size 15 mm (0.5 in.), Integral Flowmeter/Remote Flowtube

Size 25 mm (1.0 in.), Integral Flowmeter/Remote Flowtube

Size 32 mm (1.25 in.), Integral Flowmeter/Remote Flowtube

Size 40 mm (1.5 in.), Integral Flowmeter/Remote Flowtube

Size 50 mm (2.0 in.), Integral Flowmeter/Remote Flowtube

Size 65 mm (2.5 in.), Integral Flowmeter/Remote Flowtube

Size 80 mm (3.0 in.), Integral Flowmeter/Remote Flowtube

Size 100 mm (4.0 in.), Integral Flowmeter/Remote Flowtube

Size 125 mm (5.0 in.), Integral Flowmeter/Remote Flowtube

Lay Length

1 · · · · · · ·

Standard

High Grade (*8)

Electrical Connection

Optional code (See the Table of Optional Specifications)

Standard

B · · ·

C · · ·

Calibration

Integral Flowmeter with indicator (Horizontal)

Integral Flowmeter with indicator (Vertical)

Integral Flowmeter without indicator /Remote Flowtube

Indicator (*3)

-0 · · · ·

-2 · · · ·

-4 · · · ·

JIS G1/2 female

ANSI 1/2 NPT female

ISO M20

ϫ1.5 female

1 · · ·

2 · · ·

N · · ·

Size 25 mm (1.0 in.) to 125 mm (5.0 in.)

/

ٗ

T18.EPS

*1: For a tri-clamp type of size15 mm (0.5 in.)(Process connection code: HAB), prepare a 3/4 in. tri-clamp on the process pipe side.
*2: The detail dimensions of process connections (clamp/union/butt weld) are shown in the ‘EXTERNAL DIMENSIONS’ section of the sanitary type.

In case of Butt Weld type, ferrules, sleeves, or alternative must be provided by the user. User need to weld these parts to the butt weld adapter.

*3: N shall be always selected for remote flowtubes.

In the case of an integral flowmeter, select from among the following figures.

*4:

Users must consider the characteristics of selected wetted parts material and influence of process fluids.
The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is
also possible that the instrument itself can be damaged and that fragments from the instrument can contaminate the user's process fluids.
Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature
steam (150

°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.

*5: For F

OUNDATION

Fieldbus protocol, refer to IM 01E20F02-01E

*6: For PROFIBUS PA protocol, refer to IM 01E20F12-01E.
*7: Allowable fluid pressure should also be limited according to fluid temperature and pressure.
*8: In the case of calibration code C in remote type, please order a combination of flowtube and converter.

1

2

N

Tri-Clamp (3A), JIS SUS316L or SUSF316L (AISI 316L SS/EN1.4404

Equivalent or ANSI F316L SS/EN1.4435 Equivalent)(*1)

DIN32676 Clamp, JIS SUS316L or SUSF316L (AISI 316L SS/EN1.4404

Equivalent or ANSI F316L SS/EN1.4435 Equivalent)

ISO2852/SMS3016 Clamp, JIS SUS316L or SUSF316L (AISI 316L SS/

EN1.4404 Equivalent or ANSI F316L SS/EN1.4435 Equivalent)

DIN11851 Union, SUS316L or SUSF316L (AISI 316L SS/EN1.4404

Equivalent or ANSI F316L SS/EN1.4435 Equivalent)

ISO2853 Union, SUS316L or SUSF316L (AISI 316L SS/EN1.4404

Equivalent or ANSI F316L SS/EN1.4435 Equivalent)
SMS1145 Union, SUS316L or SUSF316L (AISI 316L SS/EN1.4404

Equivalent or ANSI F316L SS/EN1.4435 Equivalent)

Butt Weld for DIN 11850 Pipe Connection

(SUS316L or SUSF316L [AISI 316L SS/EN1.4404 Equivalent or ANSI

F316L SS/EN1.4435 Equivalent])

Butt Weld for ISO 2037 Pipe Connection

(SUS316L or SUSF316L [AISI 316L SS/EN1.4404 Equivalent or ANSI

F316L SS/EN1.4435 Equivalent])