beautypg.com

Yokogawa ADMAG AXF User Manual

Page 118

background image

IM 01E20D01-01E

8-2

8. EXPLOSION PROTECTED TYPE INSTRUMENT

Maximum surface temperature:

T0802.EPS

Maximum Surface

Temperature

+85

°C (+185°F)

+130

°C (+266°F)

+120

°C (+248°F)

+70

°C (+158°F)

Maximum Process

Temperature

T75

°C (+167°F)

T85

°C (+185°F)

T100

°C (+212°F)

T110

°C (+230°F)

Ambient Temp.:–40

°C to +60°C (–40°F to +140°F)

(Remote Flowtube)
ATEX Flameproof Type

Group: II
Category: 2G
EEx dme [ia] IIC T6...T3
Electrode Circuit Um: 250 Vac/dc
Excitation Circuit: 170V max
Enclosure: IP66, IP67
Temperature Class:

T0803.EPS

Temperature

Class

Maximum Process

Temperature

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

–40

°C (–40°F)

T6

Minimum Process

Temperature

T4

T5

T3

+70

°C (+158°F)

+85

°C (+185°F)

+120

°C (+248°F)

+150

°C (+302°F)

Ambient Temp.: –40

°C to +60°C (–40°F to +140°F)

ATEX Type of Protection “Dust”

Group: II
Category: 1D
Electrode Circuit Um: 250 Vac/dc
Excitation Circuit: 170V max
Enclosure: IP66, IP67
Maximum surface temperature:

T0804.EPS

Maximum Surface

Temperature

+85

°C (+185°F)

+150

°C (+302°F)

+120

°C (+248°F)

+70

°C (+158°F)

Maximum Process

Temperature

T75

°C (+167°F)

T85

°C (+185°F)

T100

°C (+212°F)

T115

°C (+239°F)

Ambient Temp.:–40

°C to +60°C (–40°F to +140°F)

(2) Electrical Connection

The type of electrical connection is stamped near the
electrical connection port according to the following
codes.

Screw Size Marking
ISO M20x1.5 female M
ANSI 1/2NPT female A

F0801.EPS

(Integral Flowmeter)

Screw Size Marking
ISO M20x1.5 female M
ANSI 1/2NPT female A

(Remote Flowtube)

(3) Installation

WARNING

• All wiring shall comply with local installation

requirements and local electrical code.

• In hazardous locations, the cable entry devices

shall be of a certified ATEX flameproof type,
suitable for the conditions of use and correctly
installed.

• Unused apertures shall be closed with suitable

flameproof certified blanking elements. (The
plug attached is flameproof certified.)

(4) Operation

(Integral Flowmeter)

WARNING

• After de-energizing, delay 20 minutes before

opening.

• Take care not to generate mechanical spark

when access to the instrument and peripheral
devices in hazardous locations.