beautypg.com

Model ejx930a, General specifications, Unit: mm(approx. inch) – Yokogawa EJX930A User Manual

Page 80: Vertical impulse piping type, Horizontal impulse piping type

background image

<10. General Specifications>

10-16

IM 01C25R01-01E

[Model EJX930A]

Unit: mm(approx. inch)

Process connector

Zero adjustment

Ground terminal

Mounting bracket

(L-type,optional)

Conduit connection

Integral indicator

(optional)

(optional)

Vent/Drain plugs

Vertical Impulse Piping Type

(Installation code 7)

143(5.63)

197(7.76)

256(10.1)

97

(3.82)

95

(3.74)

93

(3.66)

124 (4.88)

277(10.9)

52

(2.05)

39

(1.54)

110(4.33)

ш70 (2.76)

192(7.56)

*2

ш78(3.07)

132(5.2)

9

(0.35)

Low

pressure

side

High

pressure

side

2-inch pipe

(O.D. 60.5 mm)

54

(2.13)

159(6

.26)

124(4.8

8)

47

(1.85)

Mounting bracket

(Flat-type,optional)

Conduit connection

Integral indicator

(optional)

(optional)

Process

connector

Shrouding bolt*

5

Shrouding bolt*

5

197(7.76)

95(3.74)

116(4.57)

169(6.65)

68

(2.68)

93(3.66)

Drain plug

2-inch pipe

(O.D. 60.5 mm)

Vent plug

Zero adjustment

Ground terminal

Drain plug

Vent plug

54(2.13)

Low

pressure

side

High

pressure

side*

1

110(4.33)

9*

4

(0.35)

39

(1.54)

ш70 (2.76)

143(5.63)

ш78(3.07)

154(6.06)*

3

Horizontal Impulse Piping Type

(Installation code 9)

*1: When Installation code 8 is selected, high and low pressure side on above figure are reversed.

(i.e. High pressure side is on the right side.)

*2: When Option code K1, K2, K5, or K6 is selected, add 15 mm(0.59 inch) to the value in the figure.

*3: When Option code K1, K2, K5, or K6 is selected, add 30 mm(1.18 inch) to the value in the figure.

*4: 15 mm(0.59 inch) for right side high pressure.

*5: Available only when specifying the option code including ATEX, IECEx or TIIS flameproof type.

(for RTD)

Conduit connection

(for RTD)

Conduit connection

Electrical connection code 2

External temp. input code 1, 2, 3, and 4

Electrical connection code 4

External temp. input code 1, 2, 3, and 4

Electrical connection code 9

External temp. input code 0

Electrical connection code 2 and 4

External temp. input code B, C, and D

Electrical connection code 9

External temp. input code 0

Electrical connection code 4

External temp. input code 1, 2, 3, and 4

Electrical connection code 2 and 4

External temp. input code B, C, and D

6 (0.24)

54

(2.13)

48

(1.89)

54

(2.13)

6

(0.24)

48

(1.89)

Electrical connection code 2

External temp. input code 1, 2, 3, and 4

69(2.72)

116(4.57)

Cable Gland

69(2.72)

116(4.57)

Cable Gland

F1007.ai

105(4.13)

58(2.28)

Cable Gland

105(4.13)

58(2.28)

Cable Gland

This manual is related to the following products: