Model ejx930a, General specifications, Unit: mm(approx. inch) – Yokogawa EJX930A User Manual
Page 80: Vertical impulse piping type, Horizontal impulse piping type

<10. General Specifications>
10-16
IM 01C25R01-01E
[Model EJX930A]
Unit: mm(approx. inch)
Process connector
Zero adjustment
Ground terminal
Mounting bracket
(L-type,optional)
Conduit connection
Integral indicator
(optional)
(optional)
Vent/Drain plugs
Vertical Impulse Piping Type
(Installation code 7)
143(5.63)
197(7.76)
256(10.1)
97
(3.82)
95
(3.74)
93
(3.66)
124 (4.88)
277(10.9)
52
(2.05)
39
(1.54)
110(4.33)
ш70 (2.76)
192(7.56)
*2
ш78(3.07)
132(5.2)
9
(0.35)
Low
pressure
side
High
pressure
side
2-inch pipe
(O.D. 60.5 mm)
54
(2.13)
159(6
.26)
124(4.8
8)
47
(1.85)
Mounting bracket
(Flat-type,optional)
Conduit connection
Integral indicator
(optional)
(optional)
Process
connector
Shrouding bolt*
5
Shrouding bolt*
5
197(7.76)
95(3.74)
116(4.57)
169(6.65)
68
(2.68)
93(3.66)
Drain plug
2-inch pipe
(O.D. 60.5 mm)
Vent plug
Zero adjustment
Ground terminal
Drain plug
Vent plug
54(2.13)
Low
pressure
side
High
pressure
side*
1
110(4.33)
9*
4
(0.35)
39
(1.54)
ш70 (2.76)
143(5.63)
ш78(3.07)
154(6.06)*
3
Horizontal Impulse Piping Type
(Installation code 9)
*1: When Installation code 8 is selected, high and low pressure side on above figure are reversed.
(i.e. High pressure side is on the right side.)
*2: When Option code K1, K2, K5, or K6 is selected, add 15 mm(0.59 inch) to the value in the figure.
*3: When Option code K1, K2, K5, or K6 is selected, add 30 mm(1.18 inch) to the value in the figure.
*4: 15 mm(0.59 inch) for right side high pressure.
*5: Available only when specifying the option code including ATEX, IECEx or TIIS flameproof type.
(for RTD)
Conduit connection
(for RTD)
Conduit connection
Electrical connection code 2
External temp. input code 1, 2, 3, and 4
Electrical connection code 4
External temp. input code 1, 2, 3, and 4
Electrical connection code 9
External temp. input code 0
Electrical connection code 2 and 4
External temp. input code B, C, and D
Electrical connection code 9
External temp. input code 0
Electrical connection code 4
External temp. input code 1, 2, 3, and 4
Electrical connection code 2 and 4
External temp. input code B, C, and D
6 (0.24)
54
(2.13)
48
(1.89)
54
(2.13)
6
(0.24)
48
(1.89)
Electrical connection code 2
External temp. input code 1, 2, 3, and 4
69(2.72)
116(4.57)
Cable Gland
69(2.72)
116(4.57)
Cable Gland
F1007.ai
105(4.13)
58(2.28)
Cable Gland
105(4.13)
58(2.28)
Cable Gland