Connecting shielded cable for conduit use, Caution – Yokogawa EJX930A User Manual
Page 44
![background image](/manuals/360052/44/background.png)
<7. Wiring>
7-7
IM 01C25R01-01E
(4) Secure the RTD cable to the packing box by
screwing the gland into the packing box at the
position where the distance from the connector
tip of the RTD cable to the packing box will be
56.5±1mm.
Tighten approximately 1 more turn surely after
the cable can not move.
The quantity of this tightening is very important.
It leads to wiring disconnection fault when
tighten too much.
After that, tighten the clamp nut.
F0728.ai
Packing box
Rubber packing
Washer
Gland
56.5±1 mm
(5) Insert the RTD cable and firmly plug its
connector into the connecting port in the
transmitter’s terminal box.
(6) Screw the union cover to the adaptor body
which has fixed to the RTD electrical connection
at procedure (2).
Screw the union cover at least 6 full turns, and
tighten the rock nut.
(7) If the conduit piping is necessary, screw the
conduit to the union coupling after passing the
RTD cable through the conduit.
(8) Finally, confirm whether the connector is
plugged surely.
CAUTION
After the cable is plugged as explained above,
do not pull the cable or subject it to excessive
mechanical shock.
Finally, please remember to confirm whether the
connector is plugged surely.
7.6.2 Connecting Shielded Cable for
Conduit Use (External temperature
input code: -B, -C, and -D)
• RTD connection components: EJX multivariable
transmitter and RTD cable
F0721.ai
Procedure
(1) Remove the protection cap protecting the RTD
electrical connection and insert the RTD cable.
SUPPL
Y
PULSE
CHECK
ALARM
F0722.ai
(2) Remove the cap protecting the connecting
port. Then insert the RTD cable and firmly plug
the connector into the connecting port in the
transmitter's terminal box.
(3) Insert the cable through the conduit and attach
it to the RTD electrical connection.
CAUTION
Do not pull the cable or subject it to excessive
mechanical shock.