beautypg.com

Warning, 3) installation – Yokogawa EJX930A User Manual

Page 26

background image

<3. Handling Cautions>

3-9

IM 01C25R01-01E

(2) Electrical Connection
A mark indicating the electrical connection type is

stamped near the electrical connection port. These

marks are as followed.

F0307.ai

Location of the mark

Screw Size

Marking

ISO M20 × 1.5 female
ANSI 1/2 NPT female

M

N or

W

(3) Installation

WARNING

• All wiring shall comply with local installation

requirements and the local electrical code.

• There is no need for conduit seal in Division

1 and Division 2 hazardous locations

because this product is sealed at the factory.

(4) Operation

WARNING

• OPEN CIRCUIT BEFORE REMOVING

COVER. INSTALL IN ACCORDANCE WITH

THIS USER’S MANUAL

• Take care not to generate mechanical

sparking when access to the instrument and

peripheral devices in a hazardous location.

(5) Maintenance and Repair

WARNING

The instrument modification or parts replacement

by other than an authorized Representative of

Yokogawa Electric Corporation is prohibited and

will void the certification.

(6) Name Plate

F0308.ai

Name plate

• HART Communication Type

• For F

OUNDATION

Fieldbus communication type, refer to IM

01C25R03-01E.

• Modbus Communication Type

Tag plate for flameproof type

Tag plate for intrinsically safe type

Tag plate for type n protection

D

D

No. KEMA 06ATEX0037 X

EEx ia IIC T4

IP66 and IP67

Tamb. -50(-15) to 60°C MIN Tamb.for DUST -40(-15°C)

MAX PROCESS TEMP.(Tp) 120°C

T85°C(Tp.:80°C), T100°C(Tp.:100°C), T120°C(Tp.:120°C)

Supply/Pulse circuit

Ui=30 V, Ii=200 mA, Pi=0.9 W, Ci=10 nF, Li=0 mH

Sensor circuit

Uo=30 V, Io=95.4 mA, Po=468 mW, Co=11 nF, Lo=3.9 mH

WARNING

Ex nL IIC T4 Gc

IP66 / IP67

Tamb. -30(-15) to 60°C

MAX PROCESS TEMP. 120°C

Supply Circuit / Pulse Circuit Ui=30V Ci=10nF Li=0

Sensor Circuit Uo=7.4V Io=25mA Po=46.3mW Co=11nF

Lo=3.9mH

WARNING

AFTER DE-ENERGIZING, DELAY 5 MINUTES BEFORE

OPENING.

WHEN THE AMBIENT TEMP.

65°C, USE THE

HEAT-RESISTING CABLE & CABLE GLAND

≥ 90°C

POTENTIAL ELECTROSTATIC CHARGING HAZARD

POTENTIAL ELECTROSTATIC

CHARGING HAZARD

- SEE USER’S MANUAL

No. KEMA 07ATEX0109 X

Ex d IIC T6...T4 Gb, Ex tb IIIC T85°C Db

Enlcosure : IP66, IP67

TEMP. CLASS T6 T5 T4

MAX PROCESS TEMP.(Tp.) 85 100 120 °C

Tamb. -50 to 75 80 75 °C

T85°C(Tamb.:-30(-15) to 75°C, Tp.:85°C)(for Dust)

*3

*3

This manual is related to the following products: