Watlow EZ-ZONE ST User Manual
Page 14
Watlow EZ-ZONE
®
ST
•
12
•
Chapter 2 Install and Wire
1
4
2
5
3
6
contactor
contact
SSR
current
sensor
to pin 3
below
to pin 6
below
contactor
coil
A1
A2
98
99
Limi
t
Powe
r
1
4
2
5
3
6
contactor
contacts
SSR
current
sensor
to pin 3
below
to pin 6
below
contactor
coil
A1
A2
98
99
Limi
t
Powe
r
Internal wiring in an ST
with a single-pole contactor
without a limit (ST _ B - B _
_ _ - _ _ _ _).
Use single-pole contactors
for hot-to-neutral loads.
NEC does not permit neu-
tral to be switched.
Use double-pole contactors
for hot-to-hot loads. Both
hot legs must be opened to-
gether on limit conditions to
remove power from circuit.
Internal wiring in an ST
with a double-pole contactor
without a limit (ST _ B - F _
_ _ - _ _ _ _).
1
4
2
5
3
6
contactor
contact
SSR
current
sensor
to pin 3
below
to pin 6
below
contactor
coil
A1
A2
98
99
Limi
t
Powe
r
L2
K2
1
4
2
5
3
6
contactor
contact
SSR
current
sensor
to pin 3
below
to pin 6
below
contactor
coil
A1
L4
98
99
Limi
t
Powe
r
user-supplied
safety switch
output 4
internal relay
normally open
You can use output 2
(L2 and K2) to deacti-
vate the contactor coil
on an ST without a
limit (ST _ B - _ _ _ _
- _ _ _ _).
(Dotted lines repre-
sent internal wiring.)
You may remove
the factory-installed
jumper between A1
and L4 to install a
safety switch for the
limit relay (ST _ L - _
_ _ _ - _ _ _ _).
(Dotted lines repre-
sent internal wiring.)