Setup

CAS User’s Guide 49

Setup Channel Inputs

The Setup Channel Input main menu lets you access menus which
change parameters related to the channel input:

Input type

Input units

Input scaling and calibration

Input filtering

The next section explains how to use the Input menus to configure your
scanner.

Input Type

This is the first menu of the Setup Channel Inputs menu. It lets you
configure the input sensor for each channel as one of these input types:

Thermocouple types (J, K, T, S, R,B, PL-II, and N).

Linear inputs.

Skip (an input type available for unused channels.) The scanning dis-

play doesn't show channels you've set to Skip.

NOTE

If you set the input type to Skip, you won't see any of the other sub-
menus in the Setup Channel Input menu. Channel #17 toggles
between pulse and skip. If you set the input type to any thermocou-
ple, you will see the Offset menu. If you set the input type to Linear,
or you are editing the Pulse channel (#17), you will see the Input
Scaling submenus.

CHANNEL PROCESS UNITS

CHANNEL NAME ALARM STATUS

SETUP CHANNEL 02
INPUT ?

CHANNEL PROCESS UNITS

CHANNEL NAME ALARM STATUS

01 INPUT
TYPE ? J T/C