beautypg.com

Serial interface – Proface FP3900 - 19 Flat Panel" User Manual

Page 76

background image

Chapter 4 Specifications

4-37

„Serial Interface

‹ RS-232C Interface Pin Assignments and Signal Names

Connector ...........................Dsub 9 pin female

Connector set screw ...........Inch type (4-40)

Cable ..................................SIO cable manufactured by Pro-face

(FP61V-IS00-O)

Serial Interface

Baud rate : 9600 bps

Data length : 8 bits

Parity : none

Stop bit : 1

Flow control : None

Pin

No.

Signal Name

Condition

Pin Location

1

CD

Carrier Detect

*1

*1

CD, DTR, and DSR are connected together inside of the FP.

2

RD

Receive Data (FP->Host)

3

SD

Send Data (FP<-Host)

4

DTR

Data Terminal Ready*1

5

GND

Ground

6

DSR

Data Set Ready *1

7

RS

Request to Send (FP<-Host)

8

CS

Clear to Send (FP->Host)

9

NC

(Used internally)

Concerning Signal Names

Signal names used for the serial interface on FP units are designed to match the pin order used on

most PC serial interfaces, so that a straight cable can be used to connect the two. Therefore, con-

nect each pin's signal to the same signal name on the PC side.

For example, pin #2 ‘RD’ should be connected to the ‘RD’ input terminal on the PC’s connector.

Refer to section “2.4 Cable Diagrams” for each signal’s direction.

SEE

„

Optional Cable Diagrams (page2-3)

• If a cable other than the specified RS-232C cable is used, product performance

cannot be guaranteed due to the possibility of noise interfering with the FP unit's

operation.

1

5

9

6

This manual is related to the following products: