2 replacing the installation gasket, 2 replacing the installation gasket -3, Installation gasket replacement procedure – Proface FP3900 - 19 Flat Panel" User Manual
Page 148

Chapter 9 Maintenance
9-3
9.1.2
Replacing the Installation Gasket
The installation gasket protects the FP and improves its water resistance. For instructions on installing the FP
unit's gasket, refer to the following page.
Installation Gasket Replacement Procedure
(1)
Place the FP on a flat, level surface with the display
facing downwards.
(2)
Remove the old gasket from the FP.
(3)
Attach the new gasket to the FP. Be sure to insert the
gasket into the FP unit’s groove so that the gasket’s
groove sides are vertical.
(4)
Check if the gasket is attached to the FP correctly.
The upper surface of the gasket should protrude
approximately 2mm out from the groove.
SEE
5 Installation and Wiring (page5-1)
• A gasket which has been used for a long period of time may have scratches or
dirt on it, and could have lost much of its water resistance. Be sure to change the
gasket at least once a year, or when scratches or dirt become visible.
• The FP unit installation gasket’s model number is as follows.
FP-3500T Series
GP570-WP10-MS
FP-3600T Series
FP-3650T Series
FP-3710T Series
CA3-WPG15-01
FP-3900T Series
CA7-WPG19-01