Proface FP3900 - 19 Flat Panel" User Manual
Page 119
![background image](/manuals/359013/119/background.png)
FP3000 Series User Manual
5-10
Power connector specification
Wiring
Use the following wiring for FP. Those are Phoenix Contact products.
Power cable connecting
(1)
Make sure that the power cable has no power distribution.
(2)
Remove the power connector from the unit.
(3)
There are three screws located in the center of the connector. Make them loosen.
(4)
Peel some of the outside of shield part, twist core wires, and insert the wire into each cable joint.
+
24V
-
0V
FG
A frame ground terminal connected with FP unit
•
Kind of power cord is CA5-DCCNL-01 which are Digital products, or GMVSTBW2,5/3-STF-
7,62 which are Phoenix Contact
*1
products.
*1
Please contact Phoenix Contact for the details.
Recommended Drivers
SZF 1-0.6x3.5 (1204517)
Recommended stick end terminal
AI 0.75-8GY (3200519)
AI 1-8RD (3200030)
AI 1.5-8BK (3200043)
AI 2.5-8BU (3200522)
Crimp tool for recommended stick end terminal
CRIMPFOX ZA 3 (1201882)
FG
+
-
Power Cable Joint