Serial interface – Proface FP3900 - 19 Flat Panel" User Manual
Page 103
FP3000 Series User Manual
4-64
Serial Interface
RS-232C Interface Pin Assignments and Signal Names
Connector........................... Dsub 9 pin female
Connector set screw........... Inch type (4-40)
Cable.................................. SIO cable manufactured by Pro-face
(FP61V-IS00-O)
Serial Interface
Baud rate : 9600 bps
Data length : 8 bits
Parity : none
Stop bit : 1
Flow control : None
Pin
No.
Signal Name
Condition
Pin Location
1
CD
Carrier Detect
*1
*1
CD, DTR, and DSR are connected together inside of the FP.
2
RD
Receive Data (FP->Host)
3
SD
Send Data (FP<-Host)
4
DTR
Data Terminal Ready*1
5
GND
Ground
6
DSR
Data Set Ready *1
7
RS
Request to Send (FP<-Host)
8
CS
Clear to Send (FP->Host)
9
NC
(Used internally)
•
Concerning Signal Names
Signal names used for the serial interface on FP units are designed to match the pin order used on
most PC serial interfaces, so that a straight cable can be used to connect the two. Therefore, con-
nect each pin's signal to the same signal name on the PC side.
For example, pin #2 ‘RD’ should be connected to the ‘RD’ input terminal on the PC’s connector.
Refer to section “2.4 Cable Diagrams” for each signal’s direction.
SEE
Optional Cable Diagrams (page2-3)
• If a cable other than the specified RS-232C cable is used, product performance
cannot be guaranteed due to the possibility of noise interfering with the FP unit's
operation.
1
5
9
6