Chapter 9 Maintenance
9-11
9.3.2
FP-3600T Series
Replacing CA3-BLU12-01
(1)
Turn the FP unit’s power OFF (i.e. disconnect the FP unit’s power cord). Remove the three (3) I/F cov-
ers, and use a Phillips screwdriver to remove the case’s seven (7) rear attachment screws and USB
holder. Pivot the rear cover open, starting from the top of the unit.
(2)
The cover is fastened at the bottom, and hinges open.
• Since the attachment screws are small, be sure not to lose them or allow them to
fall inside the FP unit’s case.
• Be sure not to break the rear cover’s four (4) alignment tabs when you open it.
• To prevent FP unit damage, be sure the FP unit's rear cover open/close direction
is correct.
Rear Attachment Screws
USB holders