Chapter 3 PL Monitoring Features
3-37
When the setting items are specified, the battery performs error actions as shown below.
•
The [Battery] tab is displayed only when a battery is mounted, allowing you to specify the
Battery feature.
•
Battery units cannot be used with pre-installed OS type PL units that have SSD (solid-state
drive) units.
•
When power failure is recovered within the delay time specified with the [Delay time for
execution] option, the battery returns to normal operation. For the procedure to recover from a
power failure, refer to the following section.
SEE
3.3.3 When an Error Occurs (page3-14)
The delay time specified with the [Operation in power failure]-
[Delay time for execution] option. 0 to 60 seconds
When power supply is recovered within this duration,
the system can return to normal operation.
The action (Hibernate/Shut down)
selected with the
[Operation in power failure]-
[Operation] option starts.
Power failure occurred!
Power is shut down.