6 battery, 6 battery -36 – Proface APL3000B - Node Box PC User Manual
Page 97
PL3000 Series Reference Manual
3-36
3.8.6
Battery
Item
Operation
Enable
When this option is checked, the Battery Monitoring is enabled.
Error Action
Specifies the action(s) taken when the System Monitor detects that the
allowable range is exceeded.
PopupMessage
When [PopupMessage] is specified as an action, the characters entered in
the field (e.g. Battery Unit %s Error) are displayed as a popup message.
For the details about the PopupMessage feature, refer to the following
section.
Operation in power
failure
Specifies the shutdown actions to be taken when AC power supply is shut
down.
Delay time for
execution
Specifies the duration of delay time between the shutdown of AC power
supply and the execution of the operation selected with the [Operation]
option or shutdown.
Setting range: 0 to 60 seconds
The default setting is 60 seconds.
Operation
Shuts down the unit when the specified duration of delay time lapses after
the AC power supply is shut down.
• Before selecting the [Hibernate] option, the Hibernate mode should be enabled.
From [Start], select [Control Panel]-[Power Options], and on the [Hibernate] tab, put
a checkmark to the [Enable Hibernate mode (H)] option.