Proface APL3000B - Node Box PC User Manual
Page 67
PL3000 Series Reference Manual
3-6
LED Indicator
External Input Signals
The PL’s RAS interface connector uses the following input signals.
•
General-Purpose Input (DIN 2 bits)
This standard digital input is used for error/alert detection in external devices. The input signal uses two bits.
The System Monitor property of the control panel or the API-DLL can be used to enable or disable this
feature, as well as designate what type of processing is to be performed once a signal is received. (Only
the “ON” state of the DIN circuit is detected. The “OFF” state of the DIN circuit cannot be monitored.)
•
Remote Reset Input
This is the reset signal sent from an external device to the PL. When this signal is enabled, a forced reset
of the PL is performed.
The System Monitor property of the control panel or the API-DLL can be used to enable or disable this
feature.
LED Color
System Status
output condition
Green (Lit)
Normal Operation (Power is ON)
None
Green (Blinking)
System is NOT running (Soft OFF)
None
Orange (Lit)
A RAS error/alert occurred.
LED is enabled via System
Monitor Property.
Orange/Red (Blinking)
Backlight burnout is detected.
None
Not Lit
Power is OFF
-
•
To enable Remote Reset Input, make sure to check the [Enable] in the Remote reset tab of
System Monitor Property. For Remote reset of System Monitor Property, refer to the following.
Input Voltage
DC12V to 24V
Input Method
Sink / Source Input
Input Current
10mA (DC24V)
Input Resistance
3.6k
Ω
Input Points
2 points (common with external reset
input)
Operation Range
ON voltage
DC10V or more
OFF voltage
DC3V or less
Isolation Method
Photocoupler Isolation
Dielectric Strength Voltage
500V or more