8 setup guide for the system monitor property, 8 setup guide for the system monitor property -29, Setup guide for the system monitor property – Proface APL3000B - Node Box PC User Manual
Page 90: 29 3.8 setup guide for the system monitor property
Chapter 3 PL Monitoring Features
3-29
3.8
Setup Guide for the system monitor property
The System Monitor Property allows you to specify PL items you want to monitor with the RAS features and
the notification method used when errors/alerts occur. When an error/alert occurs, notification is provided
according to the method specified in the System Monitor Property.
The following table lists the operating settings that can be configured for each feature.
O: Setting available X: Setting not available
•
For procedure to set up the System Monitor Property, refer to the following section.
•
You can check the status of the PL unit you are monitoring with the RAS features on the System
Monitor screen.For details regarding the System Monitor screen, refer to the following.
Feature
Operation
Buzzer
Popup
Message
OS
Shutdown
LED
DOUT
0,1
Reset
Timeout
(sec):
Watchdog Timer
O
O
O
O
O
O
O
Voltage O
O
O
O
O
X
X
Fan
O
O
O
O
O
X
X
Temperature
O
O
O
O
O
X
X
SMART
O
O
X
O
O
X
X
DIN0,1
O
O
O
O
O
X
X
Soft Mirror
O
O
X
O
O
X
X
Remote reset
X
X
X
X
X
O
X
Backlight
O
O
X
O
O
X
X
Battery
O
O
O
O
O
X
X
• Administrator Authentication is required for executing SMART Monitoring. When a
user who does not have the administrator authentication logs in, nothing is
displayed in the item of SMART.
• DIN1 and Reset operations cannot be used at the same time.
•
The Battery feature can be specified only when a battery unit is mounted.
•
The Soft Monitor feature can be specified only when the Software Mirroring Utility is used.
SEE
3.3.2 Setup Procedure (page3-11)
SEE