PL3000 Series Reference Manual

3-8

The System Monitor property can be used to enable or disable any of these output signals.

Rated Voltage

DC12V to 24V

Maximum Load Current

120mA/point

Out Voltage Drop

1.5V or less
(at 100mA load current)

Output Points

2 points

Isolation Method

Photocoupler Isolation

Dielectric Strength Voltage

500V or more

External Power Supply

DC12V / 100mA

• Be sure to operate the unit within its maximum load current. If the maximum load

current exceeds this range, a malfunction or PL damage may occur.

• Design your electrical system by adding the load current and voltage values to the

terminal voltage. If load current value used is large, the voltage drop of 1.5V or less

will occur between the terminals.

• When connecting an induction load, be sure to connect the above drawing’s

protection diode (*1).

For connection pin location details,

+5V

R

PC357

4.7kΩ

SSTA06

Cable

*

1

DC12V

to

24V

DOUT0(-) # 7
DOUT1(-) # 8

DOUT0(+) pin # 2
DOUT1(+) pin # 3

( Interface Circuit )

Load

SEE

PL3000 Series Hardware Manual “Specifications”