Configuration control commands, Set lcd viewing angle or brightness level command, Save configuration parameters command – Maple Systems STEPware-100 User Manual
Page 59

Control
Character
Decimal
Notation
Hexadecimal
Notation
BASIC
Command
Terminal Keyboard
Keypresses
ESC
27
1B
CHR$(27)
CTRL [
STX
2
02
CHR$(2)
CTRL B
CR
13
0D
CHR$(13)
CTRL M
LF
10
0A
CHR$(10)
CTRL J
ETX
3
03
CHR$(3)
CTRL C
Control Command Format
initiator commandletter commanddata terminator
initiator =
ESC
command letter = printable ASCII character a, b, c, d, e, f, g, k, m, o, p, r, t, u,
v, w,x, y, z, B, H, K, L, M, O, P, T, X, Y, Z, ?, {, }
command data = any data required by the specified command
terminator = command terminator
STX
or line terminator
CR
,
LF
,
CR/LF
, or
ETX
Command Response Format
commanddata lineterminator
command data = any data required by the specified command
line terminator =
CR
,
LF
,
CR/LF
, or
ETX
Configuration Control Commands
Set LCD Viewing Angle or Brightness Level Command
ESC
a bias/brightness terminator
bias:
0 = 90º, 1 = 75º
or brightness: 0 = 30%, 1 = 50%, 2 = 75%, 3 = 100%
Response: none
Description: Allows the host controller to control the viewing angle of the LCD or the
display brightness of the VFD.
Example: PRINT CHR(27); “a0”; CHR(2)
Save Configuration Parameters Command
ESC
b terminator
Response: none
Description: Saves the OIT’s current setup permanently into the Flash PROM.
The saved parameters become the defaults used at power-up.
Example: PRINT CHR(27); “b”; CHR(2)
A-2
STEP1 Protocol Operation Manual
1010-0096, Rev. 04