NOVA-PV-D5251/D4251 5.25" SBC

Page 109

Î

Auto Mode

D

EFAULT

The fan adjusts its speed using these settings by

RPM:

Temperature Bound 1

Temperature Bound 2

Temperature Bound 3

Temperature Bound 4

Î

Manual Mode

The fan spins at the speed set in:

Manual Duty Cycle Setting

(Min=0, Max=100)

NOTE:

Smart fan functions are supported only when using a 4-pin fan. When

using a 3-pin fan, the functions are not supported.

Î First Boundary Temperature [60]

WARNING:

CPU failure can result if this value is set too high

When the fan is off, it will only start when the temperature exceeds this setting.

ƒ Minimum Value: 0°C

ƒ Maximum Value: 127°C

Î Second Boundary Temperature [50]

WARNING:

CPU failure can result if this value is set too high