Iv. hardware pin out – Warner Electric XCTRL-2DRV User Manual
Page 6

6 Warner Electric • +33 (0) 2 41 21 24 24
P-2097-WE-A4
IV. Hardware Pin Out
1
SD Card
External interface Parameters Savings. Possibility to save up to 8 partitions.
2
USB
External interface Use to setup the controller (Input/Output, PID, splice parameters) and to up-
load and download all parameters to a setup partition.
3
A
Digital IN
Splice selection inputs. Depending on the A, B, C bit state, select a configu-
ration of OUT1, OUT2, between a logical menu of 11 possibilities and select
PID1&2 compensation input
NPN, PNP input type Selectable.
4
B
Digital IN
5
C
Digital IN
6
Sync
Digital IN
Logical input which activate the changes of the A, B, C inputs. Depending on
logical setting, it could be activate on edge or on state.
NPN, PNP input type Selectable.
7
ErrS1
Digital Out
Error signal output to inform that Sensor1/Cell1 is out of range. Working range
can be programmed in %, Kg, Nm… 0-24VDC
8
P1
Digital IN
Parameters Partition signal input. Depending on the P1, P2, P3 bit state, it
offers a selection to all parameters tables used to setup all Input/Output, PID
and Open loop controllers
NPN, PNP input type Selectable.
9
P2
Digital IN
10
P3
Digital IN
11
Stplnt
Digital IN
Stop or reset the integral calculation of the PID
NPN, PNP input type Selectable.
12
ErrS2
Digital Out
Error signal output to inform that Sensor2/Cell2 is out of range. Working range
can be programmed in %, Kg, Nm… 0-24VDC
13
24V
Power supply
OUT
Auxiliary 24VDC Power supply, 100mA
14
Out1
Analog Output
Analog Output of PID1 or Open Loop 1 out depending on ABC selection.
Selectable: 0/+10V DC or 4/20mA.
15
Gnd
Ground
16
Ana1
Analog Input
Auxiliary Sensor Input: usually used to compensate the PID Gain versus the
roll diameter
Selectable: 0/+10V DC or 4/20mA.
17
Gnd
Ground
18
24V
Power supply
OUT
24VDC Power supply, 100 mA
19
Out2
Analog Output
Analog Output of PID2 or OL2 out depending on ABC selection.
Selectable: 0/+10V DC or 4/20mA.
20
Gnd
Ground
21
Ana2
Analog Input
Auxiliary Sensor Input: usually used to compensate the PID Gain versus the
roll diameter
Selectable: 0/+10V DC or 4/20mA.
22
Gnd
Ground
23
Ex1+
Power Out
Sensor power supply & Load Cell excitation
Selectable 0-10Vdc or 0-15Vdc, 100mA
24
Ex1-
Power Out
25
C1+
Differential Analog
Input
Load Cell and/or Dancer Arm sensor input
0-10Vdc, 0-40mVdc
26
C1-
27
Shld
Shielding
Load Cell or Sensor shielding
28
Ex2+
Power Out
Sensor power supply & Load Cell excitation
Selectable 0-10Vdc or 0-15Vdc, 100mA
29
Ex2-
Power Out
30
C2+
Differential Analog
Input
Load Cell and/or Dancer Arm sensor input
0-10V DC, 0-40mVdc
31
C2-
32
Shld
Shielding
Load Cell or Sensor shielding
This installation and Operating Manual has been arranged for the systematic installation and start-up of your
Tension Control System. Please check off each step before proceeding to the next step.