6 Warner Electric • +33 (0) 2 41 21 24 24

P-2097-WE-A4

IV. Hardware Pin Out

1

SD Card

External interface Parameters Savings. Possibility to save up to 8 partitions.

2

USB

External interface Use to setup the controller (Input/Output, PID, splice parameters) and to up-

load and download all parameters to a setup partition.

3

A

Digital IN

Splice selection inputs. Depending on the A, B, C bit state, select a configu-

ration of OUT1, OUT2, between a logical menu of 11 possibilities and select

PID1&2 compensation input

NPN, PNP input type Selectable.

4

B

Digital IN

5

C

Digital IN

6

Sync

Digital IN

Logical input which activate the changes of the A, B, C inputs. Depending on

logical setting, it could be activate on edge or on state.

NPN, PNP input type Selectable.

7

ErrS1

Digital Out

Error signal output to inform that Sensor1/Cell1 is out of range. Working range

can be programmed in %, Kg, Nm… 0-24VDC

8

P1

Digital IN

Parameters Partition signal input. Depending on the P1, P2, P3 bit state, it

offers a selection to all parameters tables used to setup all Input/Output, PID

and Open loop controllers

NPN, PNP input type Selectable.

9

P2

Digital IN

10

P3

Digital IN

11

Stplnt

Digital IN

Stop or reset the integral calculation of the PID

NPN, PNP input type Selectable.

12

ErrS2

Digital Out

Error signal output to inform that Sensor2/Cell2 is out of range. Working range

can be programmed in %, Kg, Nm… 0-24VDC

13

24V

Power supply

OUT

Auxiliary 24VDC Power supply, 100mA

14

Out1

Analog Output

Analog Output of PID1 or Open Loop 1 out depending on ABC selection.

Selectable: 0/+10V DC or 4/20mA.

15

Gnd

Ground

16

Ana1

Analog Input

Auxiliary Sensor Input: usually used to compensate the PID Gain versus the

roll diameter

Selectable: 0/+10V DC or 4/20mA.

17

Gnd

Ground

18

24V

Power supply

OUT

24VDC Power supply, 100 mA

19

Out2

Analog Output

Analog Output of PID2 or OL2 out depending on ABC selection.

Selectable: 0/+10V DC or 4/20mA.

20

Gnd

Ground

21

Ana2

Analog Input

Auxiliary Sensor Input: usually used to compensate the PID Gain versus the

roll diameter

Selectable: 0/+10V DC or 4/20mA.

22

Gnd

Ground

23

Ex1+

Power Out

Sensor power supply & Load Cell excitation

Selectable 0-10Vdc or 0-15Vdc, 100mA

24

Ex1-

Power Out

25

C1+

Differential Analog

Input

Load Cell and/or Dancer Arm sensor input

0-10Vdc, 0-40mVdc

26

C1-

27

Shld

Shielding

Load Cell or Sensor shielding

28

Ex2+

Power Out

Sensor power supply & Load Cell excitation

Selectable 0-10Vdc or 0-15Vdc, 100mA

29

Ex2-

Power Out

30

C2+

Differential Analog

Input

Load Cell and/or Dancer Arm sensor input

0-10V DC, 0-40mVdc

31

C2-

32

Shld

Shielding

Load Cell or Sensor shielding

This installation and Operating Manual has been arranged for the systematic installation and start-up of your
Tension Control System. Please check off each step before proceeding to the next step.

This manual is related to the following products: