beautypg.com

Splice selection and hold out configuration – Warner Electric XCTRL-2DRV User Manual

Page 22

background image

22 Warner Electric • +33 (0) 2 41 21 24 24

P-2097-WE-A4

5. Splice Selection and Hold Out Configuration

This menu allows the user to set-up the roll’s
change/splice. Depending on the A, B, C, Sync
Inputs state, a PID controller’s output (an Open
Loop or a defined level) can be directed to different
outputs to control another driver channel, so another
brake/roll.
The splice activation is linked to the A B C Sync
input setup. Their activation can differ depending on
their type : NPN or PNP. Please refer to the

Input/

Output Configuration tab for more information.

When the PID is running in

Linear compensation mode,

a drop down menu is displayed to select the desired
compensation input (Ana1, or Ana2).

This manual is related to the following products: