Warner Electric XCTRL-2DRV User Manual
Page 18
![background image](/manuals/354893/18/background.png)
18 Warner Electric • +33 (0) 2 41 21 24 24
P-2097-WE-A4
1. Input Selection and Setting
• Cells / Dancer Input
In this tab you can select the active input and set-up it. Select your
input with the drop down menu. Depending of the Input type the
excitation and the input voltage will be changed
Two analog inputs are available. Each input can support either a
dancer arm (BTCS620 or BTCS 254-06/10) or a load cell. Both can
be amplified or not.
• Calibration
Once the input type selected, it’s necessary to teach the Input voltage span with a calibration. The calibration
differs from one type to another: In dancer arm type, Min and Max position needs to be taught when, in load
cell type Min position is only taught and Max position voltage needs to be entered manually.
- Dancer arm calibration:
Dancer arm:
Min position: Voltage corresponding to the Max braking forces
Max position: Voltage corresponding to the Min braking forces
1) Put the Dancer Arm to Min position, press Min on the
software: Min is learnt automatically and displayed
2) Put the Dancer Arm to Max position, press Max on the
software: Max is learnt automatically and displayed
3) Click on ‘Write Current to XCtrl Partition P1P2P3’ button
to store these parameters into the integrated memory